Skip to main content
Schneider Electric LV846192

LV846192 MasterPact MTZ2 4P 1250A Drawout Circuit Breaker, 1

MPN LV846192
Active

Schneider Electric MasterPacT MTZ2, LV846192, 4P drawout circuit breaker, 1250 A rated at 40 °C, H2V 100 kA breaking capacity at 415 V AC.

$5,319.00 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846192 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846192 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth403 mm
Width556 mm
Height439 mm
Electrical life cycles10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23 A: 10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3
Mechanical life cycles15000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The LV846192 is a MasterPact MTZ2 drawout circuit breaker from the MasterPacT range, rated 1250 A at 40 °C with an H2V performance class giving 100 kA breaking capacity at 415 V AC. It's a 4-pole unit (neutral left) built for power distribution protection in switchgear — Category B selectivity means it coordinates with downstream breakers to isolate faults without blacking out the whole bus. Rated insulation voltage is 1000 V AC, operational voltage 440 V AC, and it carries a 12 kV impulse withstand. The 100 kA rated short-time withstand (Icw) holds for 1 second — enough for most upstream coordination windows — and the making capacity (Icm) hits 220 kA at 440 V.

Drawout mounting on rails or a base plate, with front and rear connection options on both the line and load sides. Connection pitch is 115 mm. Dimensions: 556 mm wide, 439 mm high, 403 mm deep — that depth matters for enclosure sizing; the breaker needs a full 403 mm clearance behind the door for the drawout mechanism to rack out.

Breaking performance and coordination

Service breaking capacity (Ics) is 100 kA at both 220/415 V and 440 V AC — that's 100% of the ultimate capacity (Icu), meaning it can reclose and carry load after a fault at that level without derating. Maximum breaking time is 25 ms; closing response time 70 ms. Electrical durability: 10,000 cycles at In under AC-23A (motor switching), 6,000 cycles under AC-3. Mechanical durability is 15,000 cycles with periodic preventive maintenance.

Standards compliance covers EN/IEC 60947-1, 60947-2, 60947-2 Annex H (for Category B selectivity), and IEC 61557-12 (for power metering if a trip unit with metering is installed).

MPN