Schneider Electric LV846196

Schneider Electric LV846196 MasterPact MTZ2 3200 A Circuit B

MPN LV846196
Active

Schneider Electric MasterPact MTZ2, LV846196, 4P drawout circuit breaker, 3200 A rated current, H2V 100 kA at 415 V AC, Category B selectivity.

$18,675.19 – $19,608.96 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846196 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846196 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth403 mm
Width556 mm
Height439 mm
Electrical life cycles5000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23 A: 5000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3
Mechanical life cycles15000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

MasterPact MTZ2 3200 A — what this breaker delivers

The LV846196 is a Schneider Electric MasterPact MTZ2 drawout circuit breaker, 4 poles, rated 3200 A at 40 °C. It carries an H2V performance class — 100 kA interrupting capacity at 415 V AC (Ics = 100 kA at 440 V AC), with a making capacity of 220 kA at 440 V AC. That puts it in the heavy industrial tier: sized for main incoming feeders, generator ties, or large transformer protection where fault currents run high. Category B selectivity means the breaker is fully rated to coordinate with downstream devices — a fault on a branch won't take this main upstream. The 100 kA Icw for 0.5 s (75 kA for 3 s) gives protection engineers room to set long-time delays for selective coordination studies.

Drawout mounting and panel fit

Drawout chassis — the breaker slides in and out of a fixed cradle, so a technician can rack it to test/disconnected position without pulling cables. Mounts on rails or a base plate; connection pitch is 115 mm. Front and rear connections are both available, which simplifies busbar routing in switchgear lineups. Dimensions: 556 mm wide × 439 mm high × 403 mm deep. That depth is the full chassis envelope — account for it in the switchgear cubicle depth, especially with rear connections and cable bending radius.

Above 40 °C, apply the manufacturer's thermal derating curve. The 1000 V insulation voltage (Ui) and 12 kV impulse withstand (Uimp) confirm it's rated for 690 V systems common in industrial plants, though the operational voltage here is 440 V AC. Electrical durability: 5000 cycles at rated current under AC-23A (switching loads), 6000 cycles under AC-3 (motor switching). Mechanical durability is 15,000 cycles with periodic preventive maintenance. For a main breaker that cycles infrequently, that's a long service life — but if this is used for frequent switching (e.g., capacitor bank or furnace control), factor in the electrical endurance limit.

Also complies with IEC 61557-12 for power metering. Pollution degree 3 (industrial environment, not clean room). IP30 protection — suitable for enclosed switchgear, not outdoor or washdown locations.