LV846201 MasterPact MTZ2 4P Circuit Breaker, 1000 A, 100 kA

MPN LV846201
Active

Schneider Electric MasterPact MTZ2, LV846201, 4P fixed circuit breaker, 1000 A at 40 °C, 100 kA Ics at 440 V AC, H2V performance.

$4,818.69 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846201 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846201 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth300 mm
Width537 mm
Height352 mm
Electrical life cycles10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23 A: 10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3
Mechanical life cycles15000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

MasterPact MTZ2 — 1000 A, 4P, Fixed-Mount Power Breaker

The LV846201 is a Schneider Electric MasterPact MTZ2 fixed-mount circuit breaker, 4 poles, rated 1000 A at 40 °C with an H2V performance class delivering 100 kA Ics at 440 V AC. It is designed for power distribution protection in main switchboards and industrial feeders where high short-circuit withstand and selectivity are critical. The breaking time is capped at 25 ms, and the closing response time at 70 ms — fast enough to limit let-through energy on a bus fault.

Short-Circuit Performance and Selectivity

Category B selectivity means the breaker is designed to coordinate with downstream devices so a fault on a branch does not take the main bus down. The Icw ratings back this up: 100 kA for 0.5 s and 1 s, 75 kA for 3 s — enough to ride through a delayed trip on a feeder. Making capacity Icm is 220 kA at 440 V AC, confirming the contacts can close into a bolted fault without welding. The H2V variant is specified for 100 kA at 415 V AC, which covers most 400 V class industrial installations. If your system is 480 V or 600 V, verify the derating curve — the Ics at 440 V is 100 kA, but higher voltages reduce that figure.

Fixed-mount on rails or a base plate. Connection pitch is 115 mm. Both upside and downside connections accept front or rear termination — choose rear for a clean switchboard layout, front for panel access. Neutral is on the right. The unit ships without a control unit (push-button control type), so factor in the Micrologic trip unit separately.

Environmental and Installation Conditions

IP30 protection — suitable for a closed switchboard, not for washdown areas. Operating altitude is 0–2000 m without derating; above that, derate per the manufacturer's curve.