Skip to main content
Schneider Electric LV846202

LV846202 MasterPact MTZ2 Circuit Breaker, 1250 A, 100 kA

MPN LV846202
Active

Schneider Electric MasterPacT MasterPact MTZ2, LV846202, fixed 4P circuit breaker, 1250 A at 40 °C, H2V 100 kA 415 V AC performance type.

$5,248.80 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846202 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846202 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth300 mm
Width537 mm
Height352 mm
Electrical life cycles10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23 A: 10000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3
Mechanical life cycles15000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The LV846202 is a MasterPact MTZ2 fixed-mount, 4-pole circuit breaker rated 1250 A at 40 °C — that is the continuous current it carries without tripping in a 40 °C ambient, so for a 35 °C switchroom you get headroom before derating applies. Category B selectivity (per EN/IEC 60947-2) confirms it is designed for that role: it withstands a partial-range fault without opening, letting the branch breaker take the hit.

Deployment context

Fixed-mount on rails or a base plate, with front and rear connection options on both the line and load sides — suits a draw-out-free switchboard where the breaker stays bolted in. IP30 enclosure protection means it is intended for indoor, locked electrical rooms, not washdown areas.

Suitability for isolation per EN/IEC 60947-2 means it provides a visible-break isolation function — no separate disconnect needed upstream.

MPN
LV846202