Schneider Electric LV846203 MasterPact MTZ2 1600A 4P Circuit

MPN LV846203
Active

Schneider Electric MasterPact MTZ2, fixed circuit breaker, 4P, 1600 A at 40 °C, H2V 100 kA 415 V AC, push-button control, without control unit.

$6,863.13 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846203 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846203 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth300 mm
Width537 mm
Height352 mm
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The LV846203 is a fixed-mount MasterPact MTZ2 circuit breaker from Schneider Electric's MasterPacT range, rated 1600 A at 40 °C with 4 poles. Category B selectivity (per IEC 60947-2) means it's designed for selective coordination downstream, so a fault on a branch trips the branch breaker, not this main. The 100 kA Icw for 1 second tells you it can pass through a delayed fault current without damage, critical for motor-starting or transformer-inrush scenarios where the breaker must hold closed during the transient. The 170 W power dissipation at rated current matters for panel thermal management — that's heat that must be vented or the enclosure derated. IP30 protection means it's for indoor switchboards, not washdown environments. The 25 ms maximum breaking time and 70 ms closing response give the protection engineer numbers for arc-flash incident energy calculations and coordination studies.

Deployment context

Fixed-mount design with front and rear connection options on both upside and downside. Mounts on rails or a base plate — typical for a main incoming breaker in a low-voltage switchboard. Neutral is on the right.

Compliant with EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H, and IEC 61557-12.

MPN
LV846203