Skip to main content
Schneider Electric LV846204

LV846204 MasterPact MTZ2 4P 2000A Circuit Breaker, 100 kA

MPN LV846204
Active

Schneider Electric MasterPacT range, MasterPact MTZ2 fixed circuit breaker, LV846204, 4P, 2000 A at 40 °C, H2V 100 kA at 415 V AC, IP30.

$7,898.04 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846204 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846204 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth300 mm
Width537 mm
Height352 mm
Electrical life cycles8000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23 A: 8000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3
Mechanical life cycles15000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The LV846204 is a fixed-mount MasterPact MTZ2 air circuit breaker from the MasterPacT range, rated 2000 A at 40 °C (In) with a 4-pole configuration (4P). Its H2V performance class delivers 100 kA Ics at 440 V AC — the service breaking capacity that governs real fault clearing without replacement. Category B selectivity means it coordinates downstream breakers to isolate only the faulted branch, keeping the rest of the distribution live. The 100 kA Icw for 1 second confirms it withstands a delayed trip coordination window, essential for selective schemes in industrial switchgear. The 2000 A frame is sized for main incoming feeders or large bus risers in power distribution. Fixed mounting on rails or base plate means it bolts into a dedicated cubicle — not a draw-out cradle — so panel layout and bus connections are permanent. Front and rear connection options give flexibility for cable or busbar entry.

The IP30 enclosure protects against tools and wires >2.5 mm but is not sealed against water — install in a dry cubicle or add an enclosure for washdown areas.

Environmental and durability ratings

Altitude derating applies above 2000 m. Mechanical durability is 15,000 cycles with periodic preventive maintenance; electrical durability is 8000 cycles at In under AC-23A. Maximum breaking time is 25 ms, closing response 70 ms. Power dissipation at rated current is 250 W — factor into cubicle ventilation calculations.

MPN
LV846204