Skip to main content
Schneider Electric LV846214

LV846214 MasterPact MTZ2 4P Drawout Circuit Breaker, 2000 A,

MPN LV846214
Active

Schneider Electric MasterPacT MasterPact MTZ2, 4P drawout circuit breaker, LV846214, rated 2000 A at 40 °C, H2V performance 100 kA at 415 V AC.

$8,003.34 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846214 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846214 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth403 mm
Width556 mm
Height439 mm
Electrical life cycles8000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-2 AC-23 A: 8000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz at In conforming to EN/IEC 60947-3
Mechanical life cycles15000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

MasterPact MTZ2 20 H2V — 2000 A drawout breaker

The LV846214 is a MasterPact MTZ2 4-pole drawout circuit breaker from the MasterPacT range, rated 2000 A at 40 °C with an H2V performance class delivering 100 kA breaking capacity at 415 V AC. It is designed for power distribution protection in industrial and commercial switchboards where Category B selectivity is required — meaning it maintains discrimination with downstream breakers during a fault, so only the affected circuit opens.

Rated service breaking capacity (Ics) is 100 kA at both 220/415 V AC and 440 V AC — full rated short-circuit capacity, not a reduced service rating. Short-time withstand (Icw) holds 100 kA for 0.5 s and 1 s, and 75 kA for 3 s, giving the protection engineer headroom for selective coordination with downstream feeders. Making capacity (Icm) reaches 220 kA at 440 V AC, confirming the breaker can close onto a bolted fault without contact welding.

Drawout mounting on rails or a base plate, with front and rear connection options on both the upside and downside. Connection pitch is 115 mm. Neutral position is on the right. The breaker is 556 mm wide, 439 mm tall, and 403 mm deep — verify the switchgear cell dimensions against these before specifying. IP30 protection conforming to EN 60529 suits enclosed panel installation; not rated for washdown environments.

Altitude rating is 0 to 2000 m without derating, 2000 to 5000 m with derating.

MPN