Schneider Electric LV846321

Schneider Electric LV846321 MasterPact MTZ2 25 HH, 2500 A, 4

MPN LV846321
Active

Schneider Electric MasterPact MTZ2 25 HH, LV846321, switch-disconnector, 2500 A, 4 poles, drawout, 100 kA Icu at 440 V AC.

$9,606.60 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846321 key specifications
ParameterValue
Control typePush-button
Main product or component typeSwitch disconnector
Voltage440 V AC 50/60 Hz conforming to EN/IEC 60947-3
Insulation voltage ui1000 V AC 50/60 Hz conforming to EN/IEC 60947-3
Current2500 A AC 50/60 Hz 440 V
Breaking capacity100 kA Icu at 220/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryAC-23 A AC-3
IP ratingIP30
Terminal pitch115 mm
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

LV846321 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-4-1
Depth403 mm
Width556 mm
Height439 mm
Electrical life cyclesAC-23 A: 5000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3
Mechanical life cycles15000 cycles with periodic preventive maintenance conforming to EN/IEC 60947-3
ApplicationDistribution
Safety categoryHH
Operating temperature-25...70 °C

Product details

The LV846321 is a Schneider Electric MasterPact MTZ2 25 HH switch-disconnector rated for 2500 A at 440 V AC, 4 poles, in a drawout chassis mount.

Rated operational current is 2500 A AC at 440 V, with utilisation categories AC-23A and AC-3 covering motor switching and mixed resistive-inductive loads. The short-time withstand rating is 75 kA for 3 seconds (or 100 kA for 1 second), which coordinates with downstream protection devices during a delayed trip. Mechanical durability is 15,000 cycles with periodic preventive maintenance; electrical durability is 5,000 cycles at 440 V under AC-23A duty.

This is a drawout switch-disconnector mounted on a chassis, with a 115 mm connection pitch. Panel cutout dimensions are 556 mm wide by 439 mm high by 403 mm deep.

MPN
LV846321