Skip to main content
Schneider Electric LV846322

LV846322 MasterPact MTZ2 32 HH Switch Disconnector, 3200 A,

MPN LV846322
Active

Schneider Electric MasterPact MTZ2 32 HH, LV846322, switch-disconnector, 3200 A, 100 kA Icu at 440 V AC, 3P drawout, isolation-rated per EN/IEC 60947-3.

$10,026.99 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846322 key specifications
ParameterValue
Control typePush-button
Main product or component typeSwitch disconnector
Voltage440 V AC 50/60 Hz conforming to EN/IEC 60947-3
Insulation voltage ui1000 V AC 50/60 Hz conforming to EN/IEC 60947-3
Current3200 A AC 50/60 Hz 440 V
Breaking capacity100 kA Icu at 220/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryAC-23 A AC-3
IP ratingIP30
Terminal pitch115 mm
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

LV846322 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-4-1
Depth403 mm
Width441 mm
Height439 mm
Electrical life cyclesAC-23 A: 5000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3
Mechanical life cycles15000 cycles with periodic preventive maintenance conforming to EN/IEC 60947-3
ApplicationDistribution
Safety categoryHH
Operating temperature-25...70 °C

Product details

The LV846322: Drawout mounting means the switch-disconnector slides into a fixed cradle on the chassis — no hardwiring of the main power connections during swap-out. The unit measures 441 mm wide by 439 mm high by 403 mm deep, so verify the switchgear compartment depth before committing the panel layout.

Rated for AC-23A and AC-3 utilisation categories: AC-23A covers switching of mixed resistive and inductive loads including occasional motor starts, while AC-3 is dedicated to squirrel-cage motor starting and switching off during running. The 100 kA Icu at 440 V matches the Ics rating — same 100 kA at 440 V — meaning the unit can be reclosed after a fault at its full rated breaking capacity without derating, which is uncommon at this current level. The Icw short-time withstand is 75 kA for 3 s or 100 kA for 1 s, giving selectivity margin for downstream breakers.

MPN
LV846322