Schneider Electric LV846348

Schneider Electric LV846348 MasterPact MTZ2 32 HH, 3200 A, 4

MPN LV846348
Active

Schneider Electric MasterPact MTZ2 32 HH switch-disconnector, LV846348, 3200 A, 4 poles, drawout, 100 kA Icu at 440 V AC.

$13,035.60 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846348 key specifications
ParameterValue
Control typePush-button
Main product or component typeSwitch disconnector
Voltage440 V AC 50/60 Hz conforming to EN/IEC 60947-3
Insulation voltage ui1000 V AC 50/60 Hz conforming to EN/IEC 60947-3
Current3200 A AC 50/60 Hz 440 V
Breaking capacity100 kA Icu at 220/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryAC-23 A AC-3
IP ratingIP30
Terminal pitch115 mm
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

LV846348 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-4-1
Depth403 mm
Width556 mm
Height439 mm
Electrical life cyclesAC-23 A: 5000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3
Mechanical life cycles15000 cycles with periodic preventive maintenance conforming to EN/IEC 60947-3
ApplicationDistribution
Safety categoryHH
Operating temperature-25...70 °C

Product details

The LV846348 is a MasterPact MTZ2 32 HH switch-disconnector rated for 3200 A continuous at 440 V AC, with a 100 kA Icu breaking capacity at both 415 V and 440 V. It's a 4-pole drawout unit with a right-neutral configuration, designed for distribution applications where isolation is required per EN/IEC 60947-3. The Ics (service breaking capacity) matches the Icu at 100 kA, so it can reclose after a fault at full rating.

Sizing and duty

Utilisation categories AC-23A and AC-3 cover motor switching and mixed resistive-inductive loads. The AC-23A rating at 440 V gives 5000 electrical cycles — enough for daily switching in a distribution panel but not for frequent motor starts. Mechanical durability is 15000 cycles with periodic preventive maintenance. Short-time withstand (Icw) is 75 kA for 3 seconds or 100 kA for 1 second, which coordinates with downstream breakers during a delayed trip. Making capacity (Icm) peaks at 220 kA at 440 V — relevant for closing into a bolted fault.

Drawout chassis mount with a 115 mm connection pitch. The 556 mm width, 439 mm height, and 403 mm depth define the cutout and clearance needed in the switchgear lineup. IP30 protection covers the front face; the drawout mechanism and rear terminals are enclosed within the switchgear cubicle. The push-button control type and contact position indicator give local status without opening the door.

Certified to EN/IEC 60947-3 for switch-disconnectors and EN/IEC 60947-2 for breaking capacity. Rated insulation voltage (Ui) is 1000 V AC, impulse withstand (Uimp) is 12 kV.

MPN