Skip to main content
Schneider Electric LV846349

Schneider Electric LV846349 MasterPact MTZ2 40HH Switch Disc

MPN LV846349
Active

Schneider Electric MasterPact MTZ2 40HH switch disconnector, LV846349, 4000 A, 100 kA Icu at 440 V AC, 4P, drawout, right Neutral.

$18,673.20 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV846349 key specifications
ParameterValue
Control typePush-button
Main product or component typeSwitch disconnector
Voltage440 V AC 50/60 Hz conforming to EN/IEC 60947-3
Insulation voltage ui1000 V AC 50/60 Hz conforming to EN/IEC 60947-3
Current4000 A AC 50/60 Hz 440 V
Utilization categoryAC-23 A AC-3
IP ratingIP30
Terminal pitch115 mm
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV846349 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-4-1
Depth403 mm
Width556 mm
Height439 mm
Electrical life cyclesAC-23 A: 5000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3
ApplicationDistribution
Safety categoryHH
Operating temperature-25...70 °C

Product details

MasterPact MTZ2 40HH — 4000 A switch disconnector for distribution

The Schneider Electric LV846349 is a MasterPact MTZ2 40HH switch disconnector rated for 4000 A at 440 V AC (50/60 Hz), with a breaking capacity of 100 kA Icu at 440 V per EN/IEC 60947-2. The 4-pole drawout chassis mount suits main or tie-breaker positions in low-voltage switchgear where full isolation and visible-break indication are required — the part is certified for isolation per EN/IEC 60947-3 and carries a contact position indicator. The drawout design means the moving portion can be racked out for maintenance without disturbing line or load connections, a standard requirement for main incomers in industrial and utility distribution. Pollution degree 3 per EN/IEC 60947-4-1 confirms it holds up in dusty or conductive-contaminant environments typical of panel rooms.

Breaking capacity and duty ratings

Rated Icu at 220/415 V and 440 V is 100 kA; the Ics (service breaking capacity) matches at 100 kA across the same voltages, meaning the switch can clear a fault and be returned to service without derating. Short-time withstand (Icw) is 75 kA for 3 s or 100 kA for 1 s, giving selectivity headroom for downstream breakers. Making capacity (Icm) peaks at 220 kA at 440 V — relevant for closing onto a bolted fault. Utilisation categories AC-23A and AC-3 cover switching of motor loads and mixed resistive-inductive loads; electrical endurance is 5000 cycles at 440 V under AC-23A. Mechanical durability is 15,000 cycles with periodic preventive maintenance.

Physical and environmental

Dimensions: 556 mm wide, 439 mm high, 403 mm deep. Mounting is drawout on a chassis support with a 115 mm connection pitch.

MPN
LV846349