Skip to main content
Schneider Electric LV847202

Schneider Electric LV847202 MasterPact MTZ1 630A Drawout Cir

MPN LV847202
Active

Schneider Electric MasterPacT MasterPact MTZ1, LV847202, drawout circuit breaker, 3P, 630 A at 40 °C, performance 150 kA 415 V AC, IEC 60947-2.

$4,000.98 – $4,201.05 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV847202 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch70 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Mechanical life cycles12500 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The LV847202 is a MasterPact MTZ1 drawout circuit breaker from Schneider Electric's MasterPacT range, rated 630 A at 40 °C with an performance class delivering 150 kA breaking capacity at 415 V AC. The drawout chassis (291 mm deep with chassis, 207.5 mm without) lets you rack the breaker out for maintenance without disturbing line and load connections, a standard requirement for switchgear where uptime matters. Rated operational voltage is 690 V AC 50/60 Hz, with an insulation voltage of 1000 V AC and impulse withstand of 12 kV — figures that confirm it's built for 690 V distribution where phase-to-phase clearance is tight. The service breaking capacity Ics tracks at 150 kA at 220/415 V, 130 kA at 440 V, and 100 kA at 500/525 V, so coordination studies should use the voltage-specific Ics, not the headline Icu. Short-time withstand Icw is 10 kA for 0.5 s, which supports selective coordination downstream — Category A selectivity, per the listing.

Drawout mounting means the breaker slides into a fixed chassis with a 70 mm connection pitch. The chassis mounts on rails or a base plate — standard for withdrawable switchgear cubicles. Upside and downside connections are both available front or rear, so you can route busbars or cables from either direction without flipping the chassis. IP30 protection on the breaker body keeps fingers out but expects enclosure-level sealing for washdown environments.

MPN
LV847202