Schneider Electric LV847202 — Air Circuit Breakers

Schneider Electric LV847202 MasterPact MTZ1 630A Drawout Cir

MPNLV847202
Active

Schneider Electric MasterPacT MasterPact MTZ1, LV847202, drawout circuit breaker, 3P, 630 A at 40 °C, performance 150 kA 415 V AC, IEC 60947-2.

$4,000.98 – $4,201.05Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LV847202 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ1
RangeMasterPacT
ApplicationPower distribution protection
Control unitWithout control unit
LV847202 — Electrical ratings
ParameterValue
Rated current (In)630 A at 40 °C
Sensor rating400 A 630 A
Rated operational voltage (Ue)690 V AC 50/60 Hz
Poles3P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)12 kV
Suitable for isolationYes conforming to EN/IEC 60947-2
LV847202 — Breaking & withstand capacity
ParameterValue
Rated ultimate breaking capacity (Icu)150 kA at 220/415 V AC 50/60 Hz 130 kA at 440 V AC 50/60 Hz 100 kA at 500/525 V AC 50/60 Hz
Rated service breaking capacity (Ics)150 kA at 220/415 V AC 50/60 Hz 130 kA at 440 V AC 50/60 Hz 100 kA at 500/525 V AC 50/60 Hz
Rated short-time withstand current (Icw)10 kA 0.5 s
Rated short-circuit making capacity (Icm)330 kA 220/415 V AC at 50/60 Hz 286 kA 440 V AC at 50/60 Hz 220 kA 500/525 V AC at 50/60 Hz 52 kA 660/690 V AC at 50/60 Hz
Performance typeL1 150 kA 415 V AC
LV847202 — Performance
ParameterValue
Breaking time, max.9 ms
Closing response time, max.50 ms
Mechanical durability (cycles)12500 cycles with periodic preventive maintenance
Electrical durability (cycles)AC-23A: 3000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-23A: 6000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3 2000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2 3000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Selectivity categoryCategory A
Power dissipation115 W
LV847202 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeDrawout
Mounting supportRails Base plate
WidthDrawout circuit breaker with chassis: 288 mm Drawout circuit breaker without chassis: 236.5 mm
HeightDrawout circuit breaker with chassis: 322 mm Drawout circuit breaker without chassis: 259.5 mm
DepthDrawout circuit breaker with chassis: 291 mm Drawout circuit breaker without chassis: 207.5 mm
Connection pitch70 mm
Upside connectionFront Rear
Downside connectionFront Rear
LV847202 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP30 conforming to EN 60529
Pollution degree3 conforming to IEC 60947-1
Operating altitude0...2000 m without derating 2000...5000 m with derating
LV847202 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H IEC 61557-12

Product details

The LV847202 is a MasterPact MTZ1 drawout circuit breaker from Schneider Electric's MasterPacT range, rated 630 A at 40 °C with an performance class delivering 150 kA breaking capacity at 415 V AC. The drawout chassis (291 mm deep with chassis, 207.5 mm without) lets you rack the breaker out for maintenance without disturbing line and load connections, a standard requirement for switchgear where uptime matters. Rated operational voltage is 690 V AC 50/60 Hz, with an insulation voltage of 1000 V AC and impulse withstand of 12 kV — figures that confirm it's built for 690 V distribution where phase-to-phase clearance is tight. The service breaking capacity Ics tracks at 150 kA at 220/415 V, 130 kA at 440 V, and 100 kA at 500/525 V, so coordination studies should use the voltage-specific Ics, not the headline Icu. Short-time withstand Icw is 10 kA for 0.5 s, which supports selective coordination downstream — Category A selectivity, per the listing.

Drawout mounting means the breaker slides into a fixed chassis with a 70 mm connection pitch. The chassis mounts on rails or a base plate — standard for withdrawable switchgear cubicles. Upside and downside connections are both available front or rear, so you can route busbars or cables from either direction without flipping the chassis. IP30 protection on the breaker body keeps fingers out but expects enclosure-level sealing for washdown environments.

Frequently asked questions

What is LV847202's breaking capacity at 415 V?

The performance class gives 150 kA Icu at 220/415 V AC, with Ics also rated 150 kA at that voltage. At 440 V Ics drops to 130 kA, and at 500/525 V to 100 kA.

Where can I buy LV847202?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

What standards does LV847202 comply with?

It complies with EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H, and IEC 61557-12. It is also suitable for isolation per EN/IEC 60947-2.

MPN