Skip to main content
Schneider Electric LV847281WW

Schneider Electric LV847281WW MicroLogic 2.0 Xi Control Unit

MPN LV847281WW
Obsolete

Schneider Electric MasterPacT MicroLogic 2.0 Xi electronic control unit, LV847281WW, LI protection, LCD display, drawout mount, 400-1600 A trip unit rating.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV847281WW specifications
ParameterValue
Control typeWired control
Display typeLCD display - 128 x 96 pixels
Trip unit typeElectronic
Main product or component typeControl unit
Voltage690 V AC, +/- 10 %
Poles4
Temp operating max70 °C
Temp operating min-35 °C
Pollution degree3 conforming to IEC 60947-1
ApplicationEquipment protection, monitoring and control
Operating temperature-25...70 °C (operating) -35 °C (for start-up of product)

Product details

What this control unit does

The Schneider Electric LV847281WW is a MicroLogic 2.0 Xi electronic control unit for MasterPacT drawout circuit breakers. It provides LI protection — long-time overload (ANSI 49) and instantaneous short-circuit (ANSI 50) — with an LCD display showing metered values. The trip unit rating covers 400 A, 630 A, 800 A, 1000 A, 1250 A, and 1600 A, so you match it to the breaker frame rating. This is a wired-control unit with a 128 x 96 pixel LCD. It measures current (I1, I2, I3, Iavg, IN RMS, Ig RMS), voltage (phase-to-phase and phase-to-neutral), active/reactive/apparent power, energy, power factor, frequency, THD, and unbalance. Accuracy runs ±0.5 % on current and voltage, ±1 % on active power and energy, ±2 % on reactive power and power factor. Measurement voltage range is 208…828 V AC phase-to-phase and 120…480 V AC phase-to-neutral at 50/60 Hz. The unit is indoor-use only, pollution degree 3, overvoltage category IV, and operates up to 5000 m altitude with voltage derating to 560 V AC.

Drawout mounting — the control unit plugs into the MasterPacT breaker cradle. No DIN-rail or panel cutout needed. The USB peer-to-peer port at 115 kbaud lets you pull logs or update settings locally without removing the unit. Protected poles configurable as 3P 3d, 4P 3d, 4P 3d + N/2, 4P 4d, or 4P 3d + OSN. Neutral protection setting follows: 1 x Ir (4P 4d), 0.5 x Ir (4P 3d + N/2), 1.6 x Ir (4P 3d + OSN), or no protection (4P 3d).

Protection and metering detail

Data recording includes time-stamped event logs, alarm logs, maintenance logs, and min/max of instantaneous values. Accuracy class: Class 0.5 on voltage unbalance, Class 1 on active energy, Class 2 on THD (V).

Designed to EN/IEC 60947-2 (circuit breakers), EN/IEC 60092-202 (marine), EN/IEC 60947-1, EN/IEC 60255-1, and EN/IEC 61010-1. Measurement category IV per IEC 61010-2-30. EMC tested to IEC 61000-4-2/3/4/5/6 and CISPR 22 Class A conducted and radiated emissions.

MPN
LV847281WW