Schneider Electric LV847287WW — Air Circuit Breakers

Schneider LV847287WW MicroLogic 7.0 Xi Control Unit, MasterP

MPNLV847287WW
Obsolete

Schneider Electric MasterPacT MicroLogic 7.0 Xi control unit, LV847287WW, wired control, LCD display, LSIV protection, 3P 4P poles, 400-3200 A trip unit ratings.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LV847287WW — Identification
ParameterValue
Product typeControl unit
RangeMasterPacT
ApplicationEquipment protection, monitoring and control
LV847287WW — Electrical ratings
ParameterValue
Rated operational voltage (Ue)600 V AC, +/- 10 %
Network typeAC
Network frequency50/60 Hz
LV847287WW — Mechanical & connection
ParameterValue
Control typeWired control
Mounting modeFixed
LV847287WW — Environmental
ParameterValue
Operating ambient temperature-25...70 °C (operating) -35 °C (for start-up of product)
Pollution degree3 conforming to IEC 60947-1
Operating altitude<= 5000 m with operational voltage derating 560 V AC
LV847287WW — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60092-202 EN/IEC 60255-1 EN/IEC 60947-2 EN/IEC 61010-1

Product details

The Schneider Electric LV847287WW is a MicroLogic 7.0 Xi control unit for MasterPacT circuit breakers. It's the brain of the breaker — handling protection, metering, and communication in one package. This is the wired-control variant with an LCD display (128 x 96 pixels) that shows current, voltage, power, energy, harmonics, and event logs. The trip unit ratings span 400 A through 3200 A, so it fits a wide range of distribution frames.

Protection and metering depth

Protection functions are LSIV: long-time overload (ANSI 49), short-time short-circuit (ANSI 51), instantaneous short-circuit (ANSI 50), and earth-leakage (ANSI 51G). The earth-leakage path is built in — no external module needed. Thermal memory is included, so the trip curve accounts for prior heating when re-closing after a fault. That matters for motor and transformer feeders where repeated overloads degrade insulation before the next trip. Metering accuracy is class 1 for active energy, class 0.5 for voltage, and class 5 for current THD. Voltage measurement covers 208-828 V phase-to-phase and 120-480 V phase-to-neutral at 50/60 Hz. The unit logs min/max values, event and alarm logs, and time-stamped data — useful for post-event analysis without a separate power monitor.

Standards and deployment context

Rated to IEC 60947-2 (circuit breakers), IEC 61010-1 (measurement equipment), and IEC 60092-202 (marine electrical systems). Overvoltage category IV and pollution degree 3 — it's designed for main distribution panels, not just sub-feeds. Indoor use only; not approved for wet locations. Operating altitude up to 5000 m with voltage derating to 560 V AC above 2000 m. EMC compliance covers IEC 61000-4-2 through -4-6 (ESD, radiated, fast transient, surge, conducted RF) and CISPR 22 Class A conducted and radiated emissions.

Frequently asked questions

Where can I buy LV847287WW and get a price?

The LV847287WW is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What poles does LV847287WW support?

The LV847287WW control unit supports 3-pole and 4-pole configurations, with protected pole options including 3P 3d, 4P 3d, 4P 3d + N/2, 4P 4d, and 4P 3d + OSN.

What protection functions does the MicroLogic 7.0 Xi provide?

The MicroLogic 7.0 Xi provides LSIV protection: long-time overload (ANSI 49), short-time short-circuit (ANSI 51), instantaneous short-circuit (ANSI 50), and earth-leakage protection (ANSI 51G). It also includes thermal memory.

MPN
LV847287WW