Schneider Electric LV847600 — Air Circuit Breakers

Schneider Electric LV847600 MicroLogic 2.0 X Control Unit, M

MPNLV847600
Active

Schneider Electric MasterPacT, MicroLogic 2.0 X electronic control unit, LI protection, LCD display 128x96 pixels, energy metering, 4P 3P pole configuration.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV847600 — Identification
ParameterValue
Product typeControl unit
RangeMasterPacT
ApplicationEquipment protection, monitoring and control

Electrical ratings

LV847600 — Electrical ratings
ParameterValue
Rated operational voltage (Ue)690 V AC, +/- 10 %
Network typeAC
Network frequency50/60 Hz

Environmental

LV847600 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C (operating) -35 °C (for start-up of product)
Pollution degree3 conforming to IEC 60947-1
Operating altitude<= 5000 m with operational voltage derating 560 V AC

Approvals

LV847600 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60092-202 EN/IEC 60947-1 EN/IEC 60255-1 EN/IEC 61010-1

Product details

The Schneider Electric LV847600 is a MicroLogic 2.0 X electronic control unit for the MasterPacT range of air circuit breakers. It provides LI protection — long-time and instantaneous short-circuit protection per ANSI 50 and ANSI 49 — plus comprehensive energy metering and system diagnostics. This is the brain that sits on the breaker, not the breaker itself. You pair it with a MasterPacT frame rated from 400 A up to 6300 A, depending on the frame size (MTZ1, MTZ2, or MTZ3). It's an electronic trip unit (not thermal-magnetic), so it gives you adjustable long-time delay in 0.5 s steps and a full set of protection curves you can tune on-site.

Measurement voltage range is 208…828 V phase-to-phase and 120…480 V phase-to-neutral — so it meters on both wye and delta configurations. Pole configuration is listed as 4P 3P, meaning the unit supports both 3-pole and 4-pole breaker frames. The neutral protection setting is configurable: 1 x Ir (4P 4d), 0.5 x Ir (4P 3d + N/2), 1.6 x Ir (4P 3d + OSN), or no protection (4P 3d). That matters when you're retrofitting a 3-pole breaker into a 4-pole installation or vice versa. Accuracy on current measurements is ±0.5 % across the full range (40…1600 x 1.2 A for MTZ1, up to 80…6300 x 1.2 A for MTZ3). Voltage accuracy is also ±0.5 %. That's Class 0.5 metering for voltage and Class 1 for active energy — good enough for submetering and energy allocation, though not utility-billing grade. It measures everything you'd expect from a power meter: phase currents, neutral current, ground fault current, all three phase-to-phase and phase-to-neutral voltages, active/reactive/apparent power and energy, power factor, frequency, THD, and unbalance. Demand values for current and power are logged.

This control unit mounts directly onto the MasterPacT breaker frame — it's not a standalone device. The breaker itself is panel-mounted, typically in a switchboard or motor control center. Communication is via Bluetooth 4.0 LE (30 kbit/s), NFC (28.8 kbaud), and USB (115 kbaud). No Ethernet or fieldbus module on this variant — you'd step up to a MicroLogic 5.0 or 6.0 for that. The Bluetooth link is handy for commissioning with a tablet or phone; the USB port is for local configuration and firmware updates. The LCD display is 128 x 96 pixels — small but readable for local readings and alarm summaries. It shows real-time metering, trip cause, breaker health state, and event logs.

Standards and environmental limits

Compliant with EN/IEC 60947-2 (low-voltage switchgear), EN/IEC 60092-202 (marine electrical installations), EN/IEC 60947-1, EN/IEC 60255-1 (measuring relays), and EN/IEC 61010-1 (safety requirements for electrical equipment). Overvoltage category IV per IEC 61010-1 — suitable for main distribution panels. Operating temperature range is -25…70 °C, with start-up capability down to -35 °C. Relative humidity up to 95 % at 55 °C. Maximum operating altitude is 5000 m with voltage derating above 2000 m (560 V AC at altitude).

Frequently asked questions

What is the closest alternative to LV847600 in the MicroLogic family?

The closest peer is the MicroLogic 5.0 X (LV847700), which adds Modbus communication and a more advanced protection set. The 2.0 X is the basic electronic trip unit with LI protection only — no Ethernet, no zone selective interlocking. If you need fieldbus integration, step up to the 5.0 X; if you only need adjustable electronic protection and local metering, the 2.0 X is the right fit.

What compliance documentation does this part carry?

It is compliant with EN/IEC 60947-2, EN/IEC 60092-202 (marine), EN/IEC 60947-1, EN/IEC 60255-1, and EN/IEC 61010-1. Overvoltage category IV. EMC compliance includes electrostatic discharge, electromagnetic fields, fast transients, surge immunity (1.2/50 µs), and conducted RF disturbances per the IEC 61000-4-x series, plus conducted and radiated emissions Class A per CISPR 22.

Where can I buy LV847600 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.