Schneider Electric LV847602

LV847602 MicroLogic 5.0 X, 4P 3P, MasterPacT

MPNLV847602
Active

Schneider Electric MasterPacT MicroLogic 5.0 X control unit, LV847602, LSI protection, 4-pole configurable, LCD display, power metering.

$1,939.29Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

LV847602 key specifications
ParameterValue
Display typeLCD display - 128 x 96 pixels
Network typeAC
Metering typeCurrent I1, I2, I3, Iavg RMS Neutral current IN RMS Ground fault current Ig RMS Voltage V12, V23, V31, VLLavg RMS Voltage V1N, V2N, V3N, VLNavg RMS Active power P, P1, P2, P3 total Reactive power Q, Q1, Q2, Q3 total Apparent power S, S1, S2, S3 total Power factor Active energy Ep IN/OUT/tot Reactive energy Eq IN/OUT/tot Apparent energy Es IN/OUT/tot Demand current I1, I2, I3, In, Iavg Demand power P, Q, S Frequency Phase sequence Earth leakage current Total current harmonic distortion THD (I) Total voltage harmonic distortion THD (V) Unbalance current Unbalance voltage
Protection typeOverload protection (long time) conforming to ANSI 49 Instantaneous short-circuit protection conforming to ANSI 50 Short time short-circuit protection conforming to ANSI 51
Type of measurementPower meter
Product or component typeControl unit
Long time delay adjustment typeAdjustable in step of 0.5 s
Short-time delay adjustment typeAdjustable
Network and machine diagnosis typeSystem (HMI) health state overview: circuit breaker health state Contacts state: circuit breaker health state MicroLogic service life: circuit breaker health state Tripping cause indication: circuit breaker tripping cause Identification card: diagnostic data Configured alarms synthesis: diagnostic data Monitored function: diagnostic data Operation: diagnostic data MicroLogic test: test Protection test: test Selectivity test: test Trip context information: crisis management Operation: advanced diagnostic Breaker service life: circuit breaker health state
Instantaneous pick-up adjustment type iiAdjustable
Measurement voltage208...828 V AC 50/60 Hz phase to phase 120...480 V AC 50/60 Hz phase to neutral
[Ue] rated operational voltage690 V AC, +/- 10 %

All specifications

LV847602 additional specifications
ParameterValue
Network frequency50/60 Hz
Frequency measurement range40...70 Hz
Poles4P 3P
Protected poles description3P 3d 4P 3d 4P 3d + N/2 4P 4d 4P 3d + OSN
Communication port protocolBluetooth 4.0 LE peer to peer 30 kbit/s NFC peer to peer conforming to ISO 15963 USB peer to peer 115 kbauds
Mounting locationIndoor use only
Pollution degree3 conforming to IEC 60947-1
Relative humidity95 % at 55 °C conforming to IEC 60068-2-30
Operating altitude<= 5000 m with operational voltage derating 560 V AC
StandardsEN/IEC 60947-2 EN/IEC 60092-202 EN/IEC 60947-1 EN/IEC 60255-1 EN/IEC 61010-1
RangeMasterPacT
AccuracyClass 5: total current harmonic distortion THD (I) Class 0.5: unbalance voltage Class 1: active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) Class 2: total voltage harmonic distortion THD (V)
Data recordingMaintenance logs Time stamping Event logs Min/max of instantaneous values Data logs Alarm logs
Thermal memoryYes
Trip unit rating400 A 630 A 800 A 1000 A 1250 A 1600 A 2000 A 2500 A 3200 A 4000 A 5000 A 6300 A
Device short nameMicroLogic 5.0 X
Energy managementMeasurement ,active, reactive and apparent energy Measurement ,electrical network Measurement ,energy
Device applicationEquipment protection, monitoring and control
Measurement accuracyCurrent I1, I2, I3, Iavg, Idemand for MTZ1: +/- 0.5 % 40...1600 x 1.2 A Current I1, I2, I3, Iavg, Idemand for MTZ2: +/- 0.5 % 40...4000 x 1.2 A Current I1, I2, I3, Iavg, Idemand for MTZ3: +/- 0.5 % 80...6300 x 1.2 A Neutral current IN: +/- 1 % Ground fault current Ig: +/- 5 % Voltage V12, V23, V31, VLLavg: +/- 0.5 % 208...690 x 1.2 V Voltage V1N, V2N, V3N, VLNavg: +/- 0.5 % 120...400 x 1.2 V Active power P, P1, P2, P3, Pdemand: +/- 1 % Reactive power Q, Q1, Q2, Q3, Qdemand: +/- 2 % Apparent power S, S1, S2, S3, Sdemand: +/- 1 % Power factor: +/- 2 % Active energy Ep IN/OUT/tot: +/- 1 % Reactive energy Ep IN/OUT/tot: +/- 2 % Apparent energy Es IN/OUT/tot: +/- 1 % Frequency: +/- 0.005 Hz Earth leakage current: +/- 10 % Unbalance current: +/- 0.5 %
Measurement categoryCategory IV conforming to IEC 61010-2-30
Overvoltage categoryIV conforming to IEC 61010-1
Trip unit technologyElectronic
Neutral protection setting1 x Ir (4P 4d) 0.5 x Ir (4P 3d + N/2) 1.6 x Ir (4P 3d + OSN) No protection (4P 3d)
Circuit breaker applicationDistribution IEC standard
Environmental characteristicWet location not approved for use conforming to IEC 61010-1
Electromagnetic compatibilityElectrostatic discharge immunity test conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Conducted and radiated emissions A conforming to CISPR 22
Trip unit protection functionsLSI
Zone selective interlocking ZSIWith
Ambient air temperature for operation-25...70 °C (operating) -35 °C (for start-up of product)
[Tr] Long-Time delay adjustment range12.5...600 s at 1.5 x Ir 0.5...24 s at 6 x Ir 0.7...16.6 s at 7.2 x Ir
[Ir] long time pick-up adjustment range0.4...1 x In adjustable in step of 1 A
[Tsd] Short-Time delay adjustment range0.1...0.4 s I²t=on 0...0.4 s I²t=off
[Isd] short-time pick-up adjustment range1.5...10 x Ir adjustable in step of 0.5 x Ir with embedded HMI 1.5...10 x Ir adjustable in step of 0.1 x Ir with Ecoreach software or MasterPact MTZ mobile app
[Ii] instantaneous pick-up adjustment range2...15 x In adjustable in step of 0.5 x In with embedded HMI 2...15 x In adjustable in step of 0.1 x In with Ecoreach software or MasterPact MTZ mobile app Ii enable on/off
[Li mode] instantaneous delay adjustment range0 ms in fast 20 ms in standard

Product details

The LV847602 is a MicroLogic 5.0 X control unit for the MasterPacT frame. It handles LSI protection (long time, short time, instantaneous), plus zone selective interlocking for tight coordination. An LCD screen (128x96) and onboard metering give you real-time current, voltage, power, and harmonics – all with voltage accuracy at Class 0.5. This is the brain for the breaker; you specify it when you need both protection and power monitoring in one package.

Mounts directly into a MasterPacT breaker cradle. The 4-pole frame is configurable for 3 or 4 protected poles (including options like N/2 or OSN). Connections for voltage sensing are required if you want full metering: 208–828 VAC phase-to-phase, 120–480 VAC phase-to-neutral. Communication setup over Bluetooth 4.0, NFC, or USB – handy for commissioning with a phone or laptop without opening the panel.

Protection & metering detail

LSI curves with adjustable long-time delay (0.5 s steps) and short-time delay. Metering covers all the usuals: I1, I2, I3, In, Ig, VLL, VLN, P, Q, S, PF, energy, THD, unbalance. Accuracy is ±0.5% on current and voltage, ±1% on active power/energy. It also logs events, alarms, min/max, and keeps a thermal memory after a trip.

Frequently asked questions

What poles does LV847602 support?

It supports 4-pole frames with configurable protected poles: 3P 3d, 4P 3d, 4P 3d+N/2, 4P 4d, or 4P 3d+OSN.

What is the range and platform for LV847602?

It's part of the Schneider MasterPacT range of air circuit breakers, designed for distribution applications.

What compliance standards does LV847602 meet?

It complies with EN/IEC 60947-1, 60947-2, 60092-202, 60255-1, 61010-1, and pollution degree 3 per IEC 60947-1.

MPN
LV847602