Skip to main content
Schneider Electric LV847609

Schneider LV847609 MicroLogic 5.0 X, MasterPacT trip unit, L

MPN LV847609
Active

Schneider Electric MasterPacT range, MicroLogic 5.0 X electronic control unit, 4P 3P, LSI protection, LCD display, 690 V AC, 50/60 Hz.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV847609 specifications
ParameterValue
Display typeLCD display - 128 x 96 pixels
Trip unit typeElectronic
Main product or component typeControl unit
Voltage690 V AC, +/- 10 %
Poles4
Temp operating max70 °C
Temp operating min-35 °C
Pollution degree3 conforming to IEC 60947-1
ApplicationEquipment protection, monitoring and control
Operating temperature-25...70 °C (operating) -35 °C (for start-up of product)

Product details

Control unit for MasterPacT breakers — what it does and what to check

The Schneider Electric LV847609 is a MicroLogic 5.0 X electronic control unit for the MasterPacT range of air circuit breakers. It provides LSI protection (long-time, short-time, instantaneous) plus comprehensive power metering and diagnostics, all via a 128 x 96 pixel LCD display. The trip unit supports multiple sensor ratings from 400 A up to 6000 A (the listed range includes 400 A, 600 A, 800 A, 1000 A, 1200 A, 1600 A, 2000 A, 2500 A, 3000 A, 3200 A, 3600 A, 4000 A, 5000 A, and 6000 A). Pole configuration is 4P 3d (three protected poles, one neutral), with options for 4P 4d, 4P 3d + N/2, and 4P 3d + OSN. Neutral protection is selectable per those configurations.

LSI protection covers overload (long-time, adjustable 0.4–1 x In in 1 A steps), short-time (adjustable delay 0–0.4 s with I²t on/off), and instantaneous short-circuit. Zone selective interlocking (ZSI) is included — this lets multiple breakers in a cascade communicate fault location, reducing stress on upstream gear during a downstream fault. Metering covers all standard electrical parameters: per-phase and average voltage (phase-to-phase and phase-to-neutral), current (I1, I2, I3, Iavg, neutral, ground fault), active/reactive/apparent power and energy, power factor, frequency, THD for current and voltage, unbalance, and demand values. Accuracy is ±0.5 % for current and voltage, ±1 % for active power and energy, ±2 % for reactive quantities. Communication ports include Bluetooth 4.0 LE (30 kbit/s), NFC (28800 baud), and USB (115 kbaud). The unit logs maintenance events, alarms, min/max values, and trip context — useful for post-fault analysis without a separate data logger.

Lifecycle and sourcing — current production, quoted to order

Standards compliance includes EN/IEC 60947-2 (circuit breakers), EN/IEC 60092-202 (marine electrical installations), EN/IEC 60947-1 (general rules), and EN/IEC 60255-1 (measuring relays).

MPN