Skip to main content
Schneider Electric LV848179 — Circuit Breaker Accessories

Schneider Electric LV848179 MasterPact MTZ2 4P 1250A Circuit

MPNLV848179
Active

Schneider Electric MasterPacT MTZ2, fixed circuit breaker, 4P, 1250 A at 40 °C, H2 100 kA 415 V AC, IP30, EN/IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LV848179 — Identification
ParameterValue
Product / component typeCircuit breaker
Product nameMasterPact MTZ2
Product rangeMasterPacT
Device applicationPower distribution protection
LV848179 — Electrical
ParameterValue
Rated current [In]1250 A at 40 °C
Rated operational voltage [Ue]690 V AC 50/60 Hz
Rated insulation voltage [Ui]1000 V AC 50/60 Hz
Rated impulse withstand voltage [Uimp]12 kV
Poles description4P
LV848179 — Protection & Performance
ParameterValue
Rated service breaking capacity [Ics]100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz 85 kA at 500/525 V AC 50/60 Hz 85 kA at 660/690 V AC 50/60 Hz
Suitability for isolationYes conforming to EN/IEC 60947-2
Mechanical durability25000 cycles with periodic preventive maintenance
Electrical durability10000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2 AC-23A: 10000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-23A: 10000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440/690 V AC 50/60 Hz conforming to EN/IEC 60947-3
LV848179 — Mechanical
ParameterValue
Connection pitch115 mm
Downside connectionFront Rear
Upside connectionFront Rear
Device short nameMTZ2 12 H2
Control typePush-button
Mounting modeFixed
Mounting supportRails Base plate
Width537 mm
Height352 mm
Depth300 mm
LV848179 — Environmental
ParameterValue
IP degree of protectionIP30 conforming to EN 60529
Pollution degree3 conforming to IEC 60947-1
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-40...85 °C
LV848179 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H IEC 61557-12

Product details

MasterPact MTZ2 12 H2 — 1250 A fixed breaker for power distribution

The LV848179 is a Schneider Electric MasterPact MTZ2 fixed circuit breaker, 4 poles, rated 1250 A at 40 °C. The device is Category B selectivity, so it coordinates with downstream breakers to isolate only the faulted branch, keeping the rest of the distribution live.

The Icw short-time withstand is 85 kA for 1 second, which matters for coordination studies: downstream devices must clear within that window or the breaker's through-fault rating is exceeded. Rated impulse withstand voltage is 12 kV, covering surge events on industrial mains. The 100 W power dissipation at rated current means the panel's thermal budget needs to account for that heat — forced ventilation or larger enclosure volume may be required if other heat sources are nearby.

Mounting and integration — fixed, front/rear connections

Fixed mounting on rails or base plate. Connection pitch is 115 mm. Both upside and downside connections accept front or rear terminations, giving flexibility for panel layout — rear connection keeps cabling out of the door swing area. Neutral is on the right. Dimensions: 537 mm wide, 352 mm high, 300 mm deep — verify the enclosure depth allows rear cable bending radius.

This is a current-production part, so lead times are typically factory-build cycles rather than last-time-buy surplus.

Frequently asked questions

What is the breaking capacity of LV848179?

The H2 performance class delivers 100 kA Ics (service breaking capacity) at 440 V AC, and 100 kA at 415 V AC. The Icu (ultimate breaking capacity) is the same 100 kA at those voltages. At 690 V AC the Ics is 85 kA.

What compliance documentation does Schneider provide for LV848179?

The breaker is certified to EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H, and IEC 61557-12. Pollution degree 3 per IEC 60947-1. Suitable for isolation per EN/IEC 60947-2.

What is the depth of LV848179?

300 mm depth, with width 537 mm and height 352 mm. Verify enclosure depth allows rear cable bending radius.

How do I get pricing and availability for LV848179?

Submit an RFQ with your quantity and target ship date. The part is sourced to order through independent distribution; current pricing and lead time are confirmed at quote time.

MPN
LV848179