Skip to main content
Schneider Electric LV848180 — Air Circuit Breakers

Schneider Electric LV848180 MasterPact MTZ2 1600 A Circuit B

MPNLV848180
Active

Schneider Electric MasterPact MTZ2, fixed circuit breaker, 4P, 1600 A at 40 °C, H2 100 kA at 415 V AC, push-button control, without control unit.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LV848180 — Identification
ParameterValue
Product typeCircuit breaker
Product nameMasterPact MTZ2
RangeMasterPacT
ApplicationPower distribution protection
Control unitWithout control unit
LV848180 — Electrical ratings
ParameterValue
Rated current (In)1600 A at 40 °C
Sensor rating800 A 1000 A 1250 A 1600 A
Rated operational voltage (Ue)690 V AC 50/60 Hz
Poles4P
Rated insulation voltage (Ui)1000 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)12 kV
Suitable for isolationYes conforming to EN/IEC 60947-2
LV848180 — Breaking & withstand capacity
ParameterValue
Rated ultimate breaking capacity (Icu)100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz 85 kA at 500/525 V AC 50/60 Hz 85 kA at 660/690 V AC 50/60 Hz
Rated service breaking capacity (Ics)100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz 85 kA at 500/525 V AC 50/60 Hz 85 kA at 660/690 V AC 50/60 Hz
Rated short-time withstand current (Icw)85 kA 0.5 s 85 kA 1 s 50 kA 3 s
Rated short-circuit making capacity (Icm)220 kA 220/415 V AC at 50/60 Hz 220 kA 440 V AC at 50/60 Hz 187 kA 500/525 V AC at 50/60 Hz 187 kA 660/690 V AC at 50/60 Hz
Performance typeH2 100 kA 415 V AC
LV848180 — Performance
ParameterValue
Breaking time, max.25 ms
Closing response time, max.70 ms
Mechanical durability (cycles)25000 cycles with periodic preventive maintenance
Electrical durability (cycles)10000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2 AC-23A: 10000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-23A: 10000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440/690 V AC 50/60 Hz conforming to EN/IEC 60947-3
Selectivity categoryCategory B
Power dissipation170 W
LV848180 — Mechanical & connection
ParameterValue
Control typePush-button
Mounting modeFixed
Mounting supportRails Base plate
Width537 mm
Height352 mm
Depth300 mm
Neutral pole positionRight
Connection pitch115 mm
Upside connectionFront Rear
Downside connectionFront Rear
LV848180 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP30 conforming to EN 60529
Pollution degree3 conforming to IEC 60947-1
Operating altitude0...2000 m without derating 2000...5000 m with derating
LV848180 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H IEC 61557-12

Product details

The Schneider Electric LV848180 is a MasterPact MTZ2 fixed-mount circuit breaker, 4-pole, rated 1600 A at 40 °C, with an H2 performance class delivering 100 kA breaking capacity at 415 V AC. It's a Category B breaker (fully selective per EN/IEC 60947-2), meaning it coordinates with downstream devices to isolate only the faulted branch — critical for maintaining uptime on a plant distribution bus.

Rated operational voltage is 690 V AC, with an insulation voltage of 1000 V AC and impulse withstand of 12 kV — this breaker is built for 480/600 V class switchgear, not just 240 V panels. Short-time withstand (Icw) is 85 kA for 1 second, which is what lets it ride through a downstream fault and stay closed for selective coordination. Power dissipation is 170 W — plan for ventilation in the enclosure. Mechanical durability is 25,000 cycles with periodic preventive maintenance; electrical durability is 10,000 cycles at 440 V AC under EN/IEC 60947-2. For motor-switching duty (AC-3), it's rated 6,000 cycles at 440/690 V. Maximum break time is 25 ms, close time 70 ms — fast enough for most coordination schemes. This breaker ships without a control unit and uses push-button control. It accepts sensor ratings from 800 A through 1600 A, so you can fit it with a lower-rated sensor if the load doesn't need the full frame. Neutral is on the right. Mounting is fixed on rails or a base plate. Altitude rating is 0–2000 m without derating, 2000–5000 m with derating.

Frequently asked questions

How do I get current pricing and availability for LV848180?

Submit an RFQ for the LV848180. Pricing and stock are confirmed at quote time through independent distribution channels.

What is LV848180's rated current and breaking capacity?

The LV848180 is rated 1600 A at 40 °C with an H2 breaking capacity of 100 kA at 415 V AC. Service breaking capacity (Ics) is 100 kA at 440 V AC.

What compliance standards does LV848180 meet?

The LV848180 is certified to EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H, and IEC 61557-12. It is suitable for isolation per EN/IEC 60947-2.

What is the closest alternative to LV848180 in the MasterPact family?

Within the MasterPact MTZ2 range, the LV848180 is the 4-pole, 1600 A, H2 (100 kA) fixed-mount variant. A lower-amp variant (e.g., 800 A frame) or a different performance class (H1, H3) would be a different order code. No direct pin-compatible alternative exists; the frame size and mounting pattern are specific to this rating.