Skip to main content
Schneider Electric LV848194

Schneider MasterPact MTZ3 LV848194, 4000 A 4P H1 100 kA

MPN LV848194
Active

Schneider Electric MasterPacT MTZ3, LV848194, fixed 4-pole circuit breaker, 4000 A rated current, H1 100 kA breaking capacity at 415 V AC, Category B, rear connection.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV848194 key specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch230 mm
Connection surface topRear
Connection surface bottomRear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

LV848194 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Depth300 mm
Width997 mm
Height352 mm
Mechanical life cycles10000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The LV848194 is a MasterPact MTZ3 fixed-mount circuit breaker rated 4000 A at 40 °C, 4 poles, with an H1 performance class delivering 100 kA Icu/Ics across the full voltage range up to 690 V AC. That 100 kA Ics at 440 V means it clears a fault and can be immediately reclosed without inspection — a key spec for selective coordination in industrial distribution where you need Category B selectivity (the breaker itself is rated Category B per IEC 60947-2). The Icw of 100 kA for 3 seconds tells you it withstands delayed clearing from downstream breakers, so it works as a main or tie breaker in a switchboard where fault-rating coordination is required. The 220 kA making capacity (Icm) covers the worst-case peak asymmetrical fault on a 415 V system. The 25 ms maximum breaking time and 80 ms closing response time are the numbers to plug into your arc-flash study.

Deployment context

The 260 W power dissipation at rated current matters for enclosure cooling calculations; factor that into the switchgear ventilation design.

The H1 performance class is Schneider's designation for 100 kA Icu at 415 V; the Ics equals Icu at all voltage levels up to 690 V, which is unusual and valuable for coordination studies.

MPN