Skip to main content
Schneider Electric LV848303

Schneider Electric LV848303 MasterPact MTZ2 25 H1, 2500 A Dr

MPN LV848303
Active

Schneider Electric MasterPacT MTZ2, LV848303, drawout circuit breaker, 4P, 2500 A at 40 °C, H1 66 kA at 415 V AC, Category B, IP30.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV848303 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Mechanical life cycles20000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The LV848303 is a Schneider Electric MasterPact MTZ2 drawout circuit breaker — 4-pole, 2500 A rated current at 40 °C, H1 performance class delivering 66 kA service breaking capacity at 415 V AC. Category B selectivity means it coordinates downstream with other breakers to isolate only the faulted branch, keeping the rest of the distribution live. Drawout mounting with front and rear connection options — the chassis stays wired while the breaker cassette slides out for maintenance or swap. Depth runs 403 mm with chassis, 300 mm without.

If your switchroom runs hotter, you derate per the manufacturer's curve. Short-time withstand (Icw) of 66 kA for up to 3 seconds supports selective coordination with downstream breakers — critical for a main breaker feeding multiple feeders. Electrical durability is rated at 6000 cycles under AC-3 (motor switching) at 440/690 V, and 5000 cycles under AC-1 at 440 V. Mechanical endurance is 20,000 cycles with periodic preventive maintenance. The 25 ms maximum breaking time means fast fault clearance, limiting arc energy and thermal stress on downstream gear.

Also listed to IEC 61557-12 for power metering compliance. Rated insulation voltage 1000 V AC, impulse withstand 12 kV.

MPN
LV848303