Skip to main content
Schneider Electric LV848303 — Circuit Breaker Accessories

Schneider Electric LV848303 MasterPact MTZ2 25 H1, 2500 A Dr

MPNLV848303
Active

Schneider Electric MasterPacT MTZ2, LV848303, drawout circuit breaker, 4P, 2500 A at 40 °C, H1 66 kA at 415 V AC, Category B, IP30.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LV848303 — Identification
ParameterValue
Product / component typeCircuit breaker
Product nameMasterPact MTZ2
Product rangeMasterPacT
Device applicationPower distribution protection
LV848303 — Electrical
ParameterValue
Rated current [In]2500 A at 40 °C
Rated operational voltage [Ue]690 V AC 50/60 Hz
Rated insulation voltage [Ui]1000 V AC 50/60 Hz
Rated impulse withstand voltage [Uimp]12 kV
Poles description4P
LV848303 — Protection & Performance
ParameterValue
Rated service breaking capacity [Ics]66 kA at 220/415 V AC 50/60 Hz 66 kA at 440 V AC 50/60 Hz 66 kA at 500/525 V AC 50/60 Hz 66 kA at 660/690 V AC 50/60 Hz
Suitability for isolationYes conforming to EN/IEC 60947-2
Mechanical durability20000 cycles with periodic preventive maintenance
Electrical durabilityAC-3: 6000 cycles 440/690 V AC 50/60 Hz conforming to EN/IEC 60947-3 2500 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2 5000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 AC-23A: 2500 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-23A: 5000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3
LV848303 — Mechanical
ParameterValue
Connection pitch115 mm
Downside connectionFront Rear
Upside connectionFront Rear
Device short nameMTZ2 25 H1
Control typePush-button
Mounting modeDrawout
Mounting supportRails Base plate
WidthDrawout circuit breaker with chassis: 556 mm Drawout circuit breaker without chassis: 493 mm
HeightDrawout circuit breaker with chassis: 439 mm Drawout circuit breaker without chassis: 300 mm
DepthDrawout circuit breaker with chassis: 403 mm Drawout circuit breaker without chassis: 300 mm
LV848303 — Environmental
ParameterValue
IP degree of protectionIP30 conforming to EN 60529
Pollution degree3 conforming to IEC 60947-1
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-40...85 °C
LV848303 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H IEC 61557-12

Product details

The LV848303 is a Schneider Electric MasterPact MTZ2 drawout circuit breaker — 4-pole, 2500 A rated current at 40 °C, H1 performance class delivering 66 kA service breaking capacity at 415 V AC. Category B selectivity means it coordinates downstream with other breakers to isolate only the faulted branch, keeping the rest of the distribution live. Drawout mounting with front and rear connection options — the chassis stays wired while the breaker cassette slides out for maintenance or swap. Depth runs 403 mm with chassis, 300 mm without.

If your switchroom runs hotter, you derate per the manufacturer's curve. Short-time withstand (Icw) of 66 kA for up to 3 seconds supports selective coordination with downstream breakers — critical for a main breaker feeding multiple feeders. Electrical durability is rated at 6000 cycles under AC-3 (motor switching) at 440/690 V, and 5000 cycles under AC-1 at 440 V. Mechanical endurance is 20,000 cycles with periodic preventive maintenance. The 25 ms maximum breaking time means fast fault clearance, limiting arc energy and thermal stress on downstream gear.

Also listed to IEC 61557-12 for power metering compliance. Rated insulation voltage 1000 V AC, impulse withstand 12 kV.

Frequently asked questions

Where can I buy LV848303 and how do I get a price?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is LV848303's listed depth?

403 mm with the drawout chassis installed; 300 mm without the chassis.

What compliance documentation does this breaker carry?

Certified to EN/IEC 60947-1, EN/IEC 60947-2 (including Annex H for selectivity), and IEC 61557-12. Suitable for isolation per EN/IEC 60947-2. Rated insulation voltage 1000 V AC, impulse withstand 12 kV.

MPN