MPN LV848333
Active

Schneider Electric MasterPacT MTZ3, LV848333, drawout circuit breaker, 4P, 4000 A at 40 °C, H1 100 kA at 415 V AC, rear connection.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV848333 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch230 mm
Connection surface topRear
Connection surface bottomRear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Mechanical life cycles10000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The LV848333 is a Schneider Electric MasterPact MTZ3 drawout circuit breaker — a 4-pole, 4000 A frame for main incoming or large feeder protection. It is the H1 performance variant, delivering 100 kA Icu at 415 V AC, with the same 100 kA across the full voltage range up to 690 V AC. The drawout chassis (included) lets you rack the breaker between connected, test, and disconnected positions without pulling cables, a standard requirement for main breakers that need periodic maintenance access.

Ratings that matter for the switchboard designer

The short-time withstand current (Icw) is 100 kA for 0.5 s, 1 s, and 3 s. Category B selectivity confirms it is designed for that role. Making capacity (Icm) is 220 kA at 415 V. This is the peak asymmetrical current the breaker can close into and latch against. Maximum closing response time is 80 ms. Insulation voltage (Ui) is 1000 V AC, operational voltage (Ue) is 690 V AC, and impulse withstand (Uimp) is 12 kV.

Drawout configuration with chassis: 403 mm deep, 1016 mm wide, 479 mm high. Without chassis: 300 mm deep, 838 mm wide, 300 mm high. The 230 mm connection pitch determines bus-bar drilling on the rear-connected pads — both upside and downside connections are rear. Mounting support options are rails or base plate. Neutral position is on the right. Standard for MasterPact 4P frames; verify bus-bar phasing if your switchboard is laid out left-neutral.

These are the core IEC standards for low-voltage switchgear and controlgear. No UL or CSA listing appears in the evidence; for North American projects, verify acceptance with the local code authority.

Environmental and durability

Altitude derating applies above 2000 m — up to 5000 m with derating. Power dissipation at rated current is 600 W — that is the heat the switchgear ventilation must extract. Mechanical durability is 10,000 cycles with periodic preventive maintenance. Electrical durability varies by duty: 6000 cycles for AC-3 (motor switching) at 440/690 V, 1500 cycles for AC-23A (occasional motor switching including inching) at the same voltages.

MPN
LV848333