Schneider Electric MasterPacT MTZ2 drawout circuit breaker, LV848436, 4P, 2000 A at 40 °C, H1 performance 66 kA at 415 V AC, Category B.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV848436 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch115 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Mechanical life cycles20000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

MasterPact MTZ2 20 H1 — 2000 A Drawout Breaker

The Schneider Electric LV848436 is a MasterPact MTZ2 20 H1 drawout circuit breaker rated 2000 A at 40 °C, 4-pole, with an H1 performance class delivering 66 kA service breaking capacity (Ics) across the full voltage range from 220/415 V through 660/690 V AC. This is a Category B breaker (selectivity type) per IEC 60947-2, meaning it's designed for full discrimination in distribution networks — a fault downstream won't trip the upstream breaker, which is the main requirement for coordinating a plant main or a feeder in a tiered power system. The drawout chassis lets you rack the breaker out for maintenance or replacement without disturbing the bus connections — a standard requirement for switchgear where uptime matters. Mounting support is on rails or base plate, with front or rear connection on both the line and load sides. The 115 mm connection pitch matches standard switchgear busbar spacing.

The Icw short-time withstand is 66 kA for 1 second (36 kA for 3 s), which gives downstream protection devices time to clear a fault before the main trips. That 1-second window is the selectivity time band you design around when setting up zone interlocking or time-delay coordination with feeder breakers. The making capacity Icm hits 145 kA at 415 V — that's the peak let-through the breaker can close into without welding contacts. Rated insulation voltage is 1000 V AC, operational voltage 690 V AC, with a 12 kV impulse withstand.

Physical Fit and Deployment Context

With the drawout chassis installed, the breaker footprint is 556 mm wide × 439 mm high × 403 mm deep. Without the chassis (for handling or storage), it's 493 mm × 300 mm × 300 mm. The IP30 enclosure protection is standard for indoor switchgear — not washdown-rated, but fine for a clean electrical room. Altitude derating starts above 2000 m.

Sensor Ratings and Control Configuration

The sensor rating for this frame covers 1000 A, 1250 A, 1600 A, and 2000 A — the breaker ships with the 2000 A rating as standard, but the same frame accepts lower-rated sensors if a future re-rate is needed. Control is push-button type with no separate control unit; the neutral position is on the right for a 4-pole configuration. Power dissipation at rated current is 470 W — relevant for enclosure ventilation calculations.