Schneider Electric LV848436 — Circuit Breaker Accessories

Schneider Electric LV848436 MasterPact MTZ2 20 H1 Drawout Br

MPNLV848436
Active

Schneider Electric MasterPacT MTZ2 drawout circuit breaker, LV848436, 4P, 2000 A at 40 °C, H1 performance 66 kA at 415 V AC, Category B.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LV848436 — Identification
ParameterValue
Product / component typeCircuit breaker
Product nameMasterPact MTZ2
Product rangeMasterPacT
Device applicationPower distribution protection
LV848436 — Electrical
ParameterValue
Rated current [In]2000 A at 40 °C
Rated operational voltage [Ue]690 V AC 50/60 Hz
Rated insulation voltage [Ui]1000 V AC 50/60 Hz
Rated impulse withstand voltage [Uimp]12 kV
Poles description4P
LV848436 — Protection & Performance
ParameterValue
Rated service breaking capacity [Ics]66 kA at 220/415 V AC 50/60 Hz 66 kA at 440 V AC 50/60 Hz 66 kA at 500/525 V AC 50/60 Hz 66 kA at 660/690 V AC 50/60 Hz
Suitability for isolationYes conforming to EN/IEC 60947-2
Mechanical durability20000 cycles with periodic preventive maintenance
Electrical durabilityAC-3: 6000 cycles 440/690 V AC 50/60 Hz conforming to EN/IEC 60947-3 6000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2 8000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 AC-23A: 6000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-23A: 8000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3
LV848436 — Mechanical
ParameterValue
Connection pitch115 mm
Downside connectionFront Rear
Upside connectionFront Rear
Device short nameMTZ2 20 H1
Control typePush-button
Mounting modeDrawout
Mounting supportRails Base plate
WidthDrawout circuit breaker with chassis: 556 mm Drawout circuit breaker without chassis: 493 mm
HeightDrawout circuit breaker with chassis: 439 mm Drawout circuit breaker without chassis: 300 mm
DepthDrawout circuit breaker with chassis: 403 mm Drawout circuit breaker without chassis: 300 mm
LV848436 — Environmental
ParameterValue
IP degree of protectionIP30 conforming to EN 60529
Pollution degree3 conforming to IEC 60947-1
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-40...85 °C
LV848436 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H IEC 61557-12

Product details

MasterPact MTZ2 20 H1 — 2000 A Drawout Breaker

The Schneider Electric LV848436 is a MasterPact MTZ2 20 H1 drawout circuit breaker rated 2000 A at 40 °C, 4-pole, with an H1 performance class delivering 66 kA service breaking capacity (Ics) across the full voltage range from 220/415 V through 660/690 V AC. This is a Category B breaker (selectivity type) per IEC 60947-2, meaning it's designed for full discrimination in distribution networks — a fault downstream won't trip the upstream breaker, which is the main requirement for coordinating a plant main or a feeder in a tiered power system. The drawout chassis lets you rack the breaker out for maintenance or replacement without disturbing the bus connections — a standard requirement for switchgear where uptime matters. Mounting support is on rails or base plate, with front or rear connection on both the line and load sides. The 115 mm connection pitch matches standard switchgear busbar spacing.

The Icw short-time withstand is 66 kA for 1 second (36 kA for 3 s), which gives downstream protection devices time to clear a fault before the main trips. That 1-second window is the selectivity time band you design around when setting up zone interlocking or time-delay coordination with feeder breakers. The making capacity Icm hits 145 kA at 415 V — that's the peak let-through the breaker can close into without welding contacts. Rated insulation voltage is 1000 V AC, operational voltage 690 V AC, with a 12 kV impulse withstand.

Physical Fit and Deployment Context

With the drawout chassis installed, the breaker footprint is 556 mm wide × 439 mm high × 403 mm deep. Without the chassis (for handling or storage), it's 493 mm × 300 mm × 300 mm. The IP30 enclosure protection is standard for indoor switchgear — not washdown-rated, but fine for a clean electrical room. Altitude derating starts above 2000 m.

Sensor Ratings and Control Configuration

The sensor rating for this frame covers 1000 A, 1250 A, 1600 A, and 2000 A — the breaker ships with the 2000 A rating as standard, but the same frame accepts lower-rated sensors if a future re-rate is needed. Control is push-button type with no separate control unit; the neutral position is on the right for a 4-pole configuration. Power dissipation at rated current is 470 W — relevant for enclosure ventilation calculations.

Frequently asked questions

What are the key ratings for LV848436?

Rated current 2000 A at 40 °C, 4-pole, H1 performance class with 66 kA Ics across 220–690 V AC, 66 kA Icw for 1 second, 145 kA Icm making capacity. Category B selectivity per IEC 60947-2.

Where can I buy LV848436 and get current pricing?

The LV848436 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a project-specific quotation with the chassis, trip unit, and any accessories.

What compliance standards does LV848436 meet?

Certified to EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H, and IEC 61557-12. Suitable for isolation per EN/IEC 60947-2. Pollution degree 3, IP30.

What is the physical size of LV848436 with the drawout chassis?

With the drawout chassis installed: 556 mm wide × 439 mm high × 403 mm deep. Without chassis: 493 mm × 300 mm × 300 mm.