Skip to main content
Schneider Electric LV848752 — Circuit Breaker Accessories

Schneider Electric LV848752 MasterPact MTZ2 40HA10 Switch Di

MPNLV848752
Active

Schneider Electric MasterPact MTZ2 40HA10 switch disconnector, LV848752, 4000 A, 105 kA/1150 V AC, 3P drawout.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV848752 — Identification
ParameterValue
Product / component typeSwitch disconnector
Product rangeMasterPact
Device applicationDistribution

Electrical

LV848752 — Electrical
ParameterValue
Network type (AC/DC)AC
Rated operational voltage [Ue]1150 V AC 50/60 Hz conforming to EN/IEC 60947-3
Rated insulation voltage [Ui]1250 V AC 50/60 Hz conforming to EN/IEC 60947-3
Rated impulse withstand voltage [Uimp]12 kV conforming to EN/IEC 60947-3
Network frequency50/60 Hz
Poles description3P

Protection & Performance

LV848752 — Protection & Performance
ParameterValue
Suitability for isolationYes conforming to EN/IEC 60947-3
Utilisation categoryAC-23A AC-3
Mechanical durability20000 cycles with periodic preventive maintenance conforming to EN/IEC 60947-3
Electrical durabilityAC-23A: 500 cycles 1150 V AC 50/60 Hz conforming to EN/IEC 60947-3
Contact position indicatorYes

Mechanical

LV848752 — Mechanical
ParameterValue
Connection pitch150 mm
Control typePush-button
Mounting modeDrawout
Mounting supportChassis
Width441 mm
Height439 mm
Depth403 mm

Environmental

LV848752 — Environmental
ParameterValue
IP degree of protectionIP30
Pollution degree3 conforming to EN/IEC 60947-4-1
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-40...85 °C

Approvals

LV848752 — Approvals
ParameterValue
StandardsEN/IEC 60947-3

Product details

The Schneider Electric LV848752 is a MasterPact MTZ2 40 HA10 switch disconnector rated for 4000 A continuous at 1150 V AC, 50/60 Hz. It carries a 105 kA peak short-circuit making capacity (Icm) at that voltage, meaning it can close onto a fault without welding contacts — the rating that matters for upstream coordination in high-fault-current distribution boards. The drawout chassis mounting lets you rack the unit out for isolation without disturbing power wiring, which saves hours during switchgear maintenance or replacement.

Duty and isolation

Rated for AC-23A and AC-3 utilisation categories, this disconnector handles both motor switching (AC-3) and mixed resistive-inductive loads including occasional motor starting (AC-23A). The 50 kA short-time withstand (Icw) for 3 seconds gives selectivity headroom downstream — a fault clears without upstream tripping as long as the downstream breaker opens within that window.

Frequently asked questions

Where can I buy LV848752 and how do I get a price?

The LV848752 is sourced and quoted to order against an RFQ through independent distribution channels. Submit an RFQ for current pricing and availability — no stock count or price figure is published here.

What is LV848752's listed depth (403 mm) on this component line?

The LV848752 has a listed depth of 403 mm, with a width of 441 mm and height of 439 mm — dimensions that govern the drawout cradle cutout and enclosure depth for switchgear integration.

What is LV848752's listed range (MasterPact) on this component line?

The LV848752 belongs to the MasterPact range, specifically the MasterPact MTZ2 40 HA10 switch-disconnector family — the high-amperage drawout platform for 4000 A distribution applications.

MPN