Schneider Electric LX0FF010 — Contactor & Starter Coils

TeSys LX0FF010 Contactor Coil, 380-400 V AC, Active

MPNLX0FF010
Active

Schneider Electric TeSys F, contactor coil LX0FF010, 380...400 V AC 50/60 Hz, latching 35...40 ms, unlatching 50...100 ms, active production.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LX0FF010 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX0FF
LX0FF010 — Electrical
ParameterValue
Control circuit voltage [Uc]380...400 V AC 50/60 Hz
Control circuit typeAC 50/60 Hz
Control circuit voltage limitsLatching: 0.85...1.1 Uc Unlatching: 0.85...1.1 Uc
Coil resistance (avg.)114.1 Ohm latching 68 °F (20 °C) 12447 Ohm unlatching 68 °F (20 °C)
LX0FF010 — Performance & Durability
ParameterValue
Operating time35...40 ms latching 50...100 ms unlatching
Max. operating rate120 cyc/h 104 °F (40 °C)
Mechanical durability1 Mcycles

Product details

Coil for TeSys F contactors — 380-400 V AC line

The LX0FF010 is a replacement contactor coil from the Schneider Electric TeSys F range, designed for contactors in the F-frame family. It operates on a 380...400 V AC control circuit at 50/60 Hz, making it a direct fit for European-standard 400 V control panels where the coil is fed from the same bus as the motor power. Latching time is 35...40 ms; unlatching takes 50...100 ms. The coil resistance measures 114.1 Ω for the latching winding and 12447 Ω for the unlatching winding at 68 °F (20 °C). These values let you verify the coil against the contactor's published pick-up and drop-out curves without pulling the contactor from the panel.

These figures govern replacement intervals in high-duty-cycle applications like conveyor or pump cycling.

Integration notes

The coil mounts directly into the TeSys F contactor frame — no adapter plate or wiring harness modification needed. Control voltage limits are 0.85...1.1 Uc for both latching and unlatching, so the coil holds in reliably at 323 V AC (the lower limit) and tolerates line swell up to 440 V AC. Verify the control transformer tap before wiring.

Frequently asked questions

What is the control voltage for LX0FF010?

The control circuit voltage is 380...400 V AC at 50/60 Hz. The coil holds within 0.85 to 1.1 times Uc for both latching and unlatching.

What are the operating times for this coil?

Latching time is 35...40 ms; unlatching time is 50...100 ms. These are the manufacturer's specified ranges at rated voltage.

What is the mechanical durability rating?

The LX0FF010 is rated for 1 million mechanical cycles, with a maximum operating rate of 120 cycles per hour at 104 °F (40 °C).