Skip to main content
Schneider Electric LX0FG005 — Contactor & Starter Coils

Schneider Electric LX0FG005 TeSys F Contactor Coil, 48 V AC/

MPNLX0FG005
Obsolete

Schneider Electric, TeSys F series, contactor coil, LX0FG005, 48 V AC/DC control voltage, latching 35-40 ms, unlatching 50-100 ms.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX0FG005 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX0FG
LX0FG005 — Electrical
ParameterValue
Control circuit voltage [Uc]48 V AC 50...400 Hz 48 V DC
Control circuit typeAC 50...400 Hz DC standard
Control circuit voltage limitsLatching: 0.85...1.1 Uc Unlatching: 0.85...1.1 Uc
Coil resistance (avg.)1.42 Ohm latching 68 °F (20 °C) 220 Ohm unlatching 68 °F (20 °C)
LX0FG005 — Performance & Durability
ParameterValue
Operating time35...40 ms latching 50...100 ms unlatching
Max. operating rate120 cyc/h 104 °F (40 °C)
Mechanical durability1 Mcycles

Product details

It is the part you swap when the coil burns out or the control voltage changes, not the whole contactor assembly. Rated for 48 V AC 50...400 Hz or 48 V DC control circuits, with a latching operating time of 35...40 ms and unlatching at 50...100 ms. The coil holds within 0.85...1.1 Uc of the rated voltage. Coil resistance measures 1.42 Ohm for the latching winding and 220 Ohm for the unlatching winding at 68 °F (20 °C). That dual-winding design is typical of mechanically-latched contactors — the latching coil pulls the armature in, and the unlatching coil releases it, so the contactor stays closed without continuous power draw.

The 48 V AC/DC control voltage is the headline fit parameter. This coil works on either AC or DC control, which simplifies stocking — one part covers both control schemes. The 50...400 Hz frequency range on the AC side covers standard 50 Hz and 60 Hz industrial supplies, plus higher-frequency applications like 400 Hz aircraft ground power. Mechanical durability is rated at 1 Mcycles, meaning the coil and its mechanical linkage are good for one million operations before wear-out becomes a concern. That is a standard industrial rating for a contactor coil in this class — fine for most process and conveyor applications, but worth noting for high-cycling duty like a stamping press or rapid-indexing line. Maximum operating rate is 120 cycles per hour at 104 °F (40 °C). Exceed that rate and the coil will overheat.

MPN
LX0FG005