Schneider Electric LX0FG008 — Contactor & Starter Coils

TeSys LX0FG008 Contactor Coil, 220-230 V AC/DC, Obsolete

MPNLX0FG008
Obsolete

TeSys F contactor coil, LX0FG008, 220...230 V AC/DC, latching 35...40 ms / unlatching 50...100 ms, 26.27 Ω latching coil resistance.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX0FG008 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX0FG
LX0FG008 — Electrical
ParameterValue
Control circuit voltage [Uc]220...230 V AC 50...400 Hz 220...230 V DC
Control circuit typeAC 50...400 Hz DC standard
Control circuit voltage limitsLatching: 0.85...1.1 Uc Unlatching: 0.85...1.1 Uc
Coil resistance (avg.)26.27 Ohm latching 68 °F (20 °C) 4729 Ohm unlatching 68 °F (20 °C)
LX0FG008 — Performance & Durability
ParameterValue
Operating time35...40 ms latching 50...100 ms unlatching
Max. operating rate120 cyc/h 104 °F (40 °C)
Mechanical durability1 Mcycles

Product details

The LX0FG008 is a replacement contactor coil for the TeSys F range — the heavy-duty contactor family rated for motor and resistive loads up to the contactor frame's rating. This is the coil only, not the full contactor assembly; it bolts into the existing TeSys F contactor base. Control circuit voltage is 220...230 V, and the coil accepts both AC (50...400 Hz) and DC supply — unusual versatility for a single coil that simplifies stocking for panels that mix control transformer and DC power supply architectures. The latching coil draws 26.27 Ω at 68 °F (20 °C); the unlatching coil measures 4729 Ω at the same temperature. Operating times are 35...40 ms latching and 50...100 ms unlatching, which is standard for a frame this size — fast enough for most motor starting and isolation sequences.

Key ratings in context

Rated for 220...230 V AC/DC control circuits with a tolerance band of 0.85...1.1 Uc for both latching and unlatching. That means the coil holds in down to about 187 V and up to 253 V — useful if your control transformer sags under load or your DC bus regulation is loose. That is adequate for occasional switching in HVAC or pump panels but not for high-speed sorting or press lines.

Frequently asked questions

What is the closest alternative to LX0FG008?

There is no official direct replacement announced. For an exact fit, you need to source the LX0FG008 itself through surplus channels. A panel rework may be required to adapt a different coil or contactor family.

What control voltage does LX0FG008 accept?

220...230 V AC (50...400 Hz) or 220...230 V DC. The coil accepts both AC and DC on the same terminals.

What is the latching and unlatching time?

Latching: 35...40 ms. Unlatching: 50...100 ms.