Schneider Electric LX0FG020 — Contactor & Starter Coils

Schneider LX0FG020 TeSys F contactor coil, 208 V AC/DC

MPNLX0FG020
Active

Schneider Electric, TeSys F, contactor coil, LX0FG020, 208 V AC/DC control voltage, 35...40 ms latching, 1 Mcycles mechanical durability.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LX0FG020 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX0FG
LX0FG020 — Electrical
ParameterValue
Control circuit voltage [Uc]208 V AC 50...400 Hz 208 V DC
Control circuit typeAC 50...400 Hz DC standard
Control circuit voltage limitsLatching: 0.85...1.1 Uc Unlatching: 0.85...1.1 Uc
Coil resistance (avg.)21.3 Ohm latching 68 °F (20 °C) 3169 Ohm unlatching 68 °F (20 °C)
LX0FG020 — Performance & Durability
ParameterValue
Operating time35...40 ms latching 50...100 ms unlatching
Max. operating rate120 cyc/h 104 °F (40 °C)
Mechanical durability1 Mcycles

Product details

The LX0FG020 is a TeSys F contactor coil from Schneider Electric, designed to energize the magnetic circuit of TeSys F contactors. It operates on a 208 V control circuit, accepting either AC (50...400 Hz) or DC supply, which simplifies panel wiring when both supply types are available. The coil's latching time is 35...40 ms and unlatching takes 50...100 ms, meaning the contactor pulls in quickly but releases with a slight intentional delay to avoid chatter from brief supply dips. The control voltage must stay within 0.85...1.1 Uc for reliable operation — at 208 V nominal, that's 176.8...228.8 V.

Duty cycle and mechanical life

Rated for 1 million mechanical cycles and a maximum operating rate of 120 cycles per hour at 104 °F (40 °C), this coil suits applications with moderate switching frequency — conveyor sections, pump start/stop, or fan cycling. The average coil resistance is 21.3 Ω for the latching winding and 3169 Ω for the unlatching winding at 68 °F (20 °C), which lets you calculate inrush and holding current for your control transformer sizing.

Frequently asked questions

What is the control voltage for LX0FG020?

The control circuit voltage is 208 V, accepting either AC (50...400 Hz) or DC supply. The operating limits are 0.85...1.1 Uc, so the coil will reliably pick up between 176.8 V and 228.8 V.

What are the operating times for this coil?

Latching time is 35...40 ms, unlatching time is 50...100 ms. The maximum operating rate is 120 cycles per hour at 104 °F (40 °C).

What is the mechanical durability of LX0FG020?

Rated for 1 million mechanical cycles under normal operating conditions.