Schneider Electric LX0FH005 — Contactor & Starter Coils

TeSys LX0FH005 Contactor Coil, 48 V AC/DC, Obsolete

MPNLX0FH005
Obsolete

TeSys F, contactor coil, LX0FH005, 48 V AC/DC, 50...100 ms unlatching, 1 Mcycles mechanical durability.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX0FH005 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX0FH
LX0FH005 — Electrical
ParameterValue
Control circuit voltage [Uc]48 V AC 50...400 Hz 48 V DC
Control circuit typeAC 50...400 Hz DC standard
Control circuit voltage limitsLatching: 0.85...1.1 Uc Unlatching: 0.85...1.1 Uc
Coil resistance (avg.)1.34 Ohm latching 68 °F (20 °C) 183.4 Ohm unlatching 68 °F (20 °C)
LX0FH005 — Performance & Durability
ParameterValue
Operating time50...100 ms unlatching 45...50 ms latching
Max. operating rate120 cyc/h 104 °F (40 °C)
Mechanical durability1 Mcycles

Product details

The LX0FH005 is a TeSys F contactor coil — the replaceable solenoid that pulls in and holds the main power contacts on a TeSys F frame contactor. It runs on a 48 V AC/DC control circuit, accepting both AC 50...400 Hz and DC standard supplies, so it fits panels where the control voltage is already 48 V and you want one coil part for either waveform. Operating time runs 50...100 ms for unlatching and 45...50 ms for latching, which is typical for a contactor of this frame size. The coil resistance at 20 °C is 1.34 Ω for the latching winding and 183.4 Ω for the unlatching winding — numbers worth checking if you're verifying a replacement against an existing circuit's pull-in current. Rated for 1 Mcycles mechanical durability and a maximum operating rate of 120 cycles per hour at 40 °C, so it's built for standard switching duty on conveyors, pumps, or compressors — not high-speed cycling applications.

There is no official manufacturer successor order code for this specific coil.

What to verify before specifying

The control circuit voltage limits are 0.85...1.1 Uc for both latching and unlatching — so at 48 V nominal, the coil holds in down to about 40.8 V and must not see more than 52.8 V. If your panel's 48 V bus sags under load, this coil may drop out before the contactor does. Because this is a service part (category 18401-WORLD SERVICE PARTS), it was originally intended as a field-replacement item for installed TeSys F contactors, not as a new-design component. If you are building a new panel, the better move is to select a current-production coil from the same frame family that matches your contactor's voltage.

Frequently asked questions

What range does LX0FH005 belong to?

It is part of the TeSys range, specifically the TeSys F series of contactors and accessories.

How do I source LX0FH005 if it is obsolete?

Through the surplus and broker channel. We can source it to order against an RFQ — no stock is held on the shelf.

MPN