Skip to main content
Schneider Electric LX0FJ020 — Contactor & Starter Coils

TeSys LX0FJ020 Contactor Coil, 208 V AC/DC, Active

MPNLX0FJ020
Active

TeSys F, contactor coil, LX0FJ020, 208 V AC/DC control circuit, 50-100 ms unlatching / 40-75 ms latching.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LX0FJ020 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX0FJ
LX0FJ020 — Electrical
ParameterValue
Control circuit voltage [Uc]208 V AC 50...400 Hz 208 V DC
Control circuit typeAC 50...400 Hz DC standard
Control circuit voltage limitsLatching: 0.85...1.1 Uc Unlatching: 0.85...1.1 Uc
Coil resistance (avg.)24.4 Ohm latching 68 °F (20 °C) 2643 Ohm unlatching 68 °F (20 °C)
LX0FJ020 — Performance & Durability
ParameterValue
Operating time50...100 ms unlatching 40...75 ms latching
Max. operating rate120 cyc/h 104 °F (40 °C)
Mechanical durability1 Mcycles

Product details

Coil for TeSys F contactors — 208 V AC/DC

The LX0FJ020 is a replacement coil for the TeSys F contactor range, rated for a 208 V control circuit that accepts both AC (50–400 Hz) and DC supply. The latching coil draws 208 V at a resistance of 24.4 Ω (at 20 °C), while the unlatching coil measures 2643 Ω at the same temperature — the large ratio tells you the unlatching circuit is a low-current hold path, not a continuous power draw. Operating time is specified as 50–100 ms for unlatching and 40–75 ms for latching. That's fast enough for most motor-switching sequences but worth checking if your application requires coordinated timing with upstream devices. The maximum operating rate is 120 cycles per hour at 40 °C — above that, the thermal rise in the coil may exceed the insulation class.

Integration notes

The coil mounts directly onto the TeSys F contactor frame — no adapter or bracket needed. Control circuit voltage limits are 0.85–1.1 Uc for both latching and unlatching, so the supply must stay within 177–229 V for reliable pick-up and drop-out. Mechanical durability is rated at 1 million cycles, which aligns with the contactor's own mechanical life under light duty.

Frequently asked questions

What is the control circuit voltage for LX0FJ020?

The coil is rated for 208 V AC (50–400 Hz) or 208 V DC. The operating voltage range is 0.85–1.1 Uc, so the supply must stay between approximately 177 V and 229 V.

What is the operating time of this coil?

Unlatching time is 50–100 ms; latching time is 40–75 ms. The maximum operating rate is 120 cycles per hour at 40 °C.

What is the mechanical durability of LX0FJ020?

Rated at 1 million cycles mechanical. This matches the contactor frame's mechanical life under typical resistive or motor loads.

MPN
LX0FJ020