Skip to main content
Schneider Electric LX0FL010 — Contactor & Starter Coils

TeSys LX0FL010 Contactor Coil, 380-400 V AC, Obsolete

MPNLX0FL010
Obsolete

Schneider Electric TeSys F, contactor coil, LX0FL010, 380...400 V AC 50/60 Hz, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX0FL010 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX0FL
LX0FL010 — Electrical
ParameterValue
Control circuit voltage [Uc]380...400 V AC 50/60 Hz
Control circuit typeAC 50/60 Hz
Control circuit voltage limitsLatching: 0.85...1.1 Uc Unlatching: 0.85...1.1 Uc
Coil resistance (avg.)60.95 Ohm latching 68 °F (20 °C) 10676 Ohm unlatching 68 °F (20 °C)
LX0FL010 — Performance & Durability
ParameterValue
Operating time50...100 ms unlatching 40...80 ms latching
Max. operating rate120 cyc/h 104 °F (40 °C)
Mechanical durability1 Mcycles

Product details

The LX0FL010 is a TeSys F contactor coil from Schneider Electric, rated for 380...400 V AC control circuits at 50/60 Hz. It is the replacement coil for TeSys F contactors in that voltage range — the part you order when the original coil fails or a panel build calls for a 400 V AC control loop. Operating time is 50...100 ms on unlatching and 40...80 ms on latching, with a maximum operating rate of 120 cycles per hour at 104 °F (40 °C). Mechanical durability is rated at 1 million cycles. Coil resistance at 68 °F (20 °C) is 60.95 Ω for the latching winding and 10,676 Ω for the unlatching winding — a wide differential that tells you this is a two-winding economizer design: the latching winding pulls the armature in, then the unlatching winding holds it with lower power dissipation.

Sourcing reality — obsolete, sourced to order

A 380-400 V AC TeSys F coil with matching pinout and mounting footprint is the functional equivalent, but verify compatibility against the existing contactor base before ordering.

Frequently asked questions

What is the control voltage for this coil?

380...400 V AC at 50/60 Hz. The control circuit voltage limits are 0.85 to 1.1 times Uc for both latching and unlatching.

What is the operating time and cycle rate?

Unlatching time is 50 to 100 ms; latching time is 40 to 80 ms. Maximum operating rate is 120 cycles per hour at 104 °F (40 °C).

What is the mechanical durability rating?

1 million cycles.

MPN
LX0FL010