Skip to main content
Schneider Electric LX0FL224 — Contactor & Starter Coils

TeSys LX0FL224 contactor coil, 220 V latching / 24 V unlatch

MPNLX0FL224
Obsolete

Schneider Electric TeSys F series, contactor coil LX0FL224, 220 V latching / 24 V unlatching AC/DC control circuit.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX0FL224 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX0FL
LX0FL224 — Electrical
ParameterValue
Control circuit voltage [Uc]220 V AC 50...400 Hz latching 24 V AC 50...400 Hz unlatching 220 V DC latching 24 V DC unlatching
Control circuit typeAC 50...400 Hz DC standard
Control circuit voltage limitsLatching: 0.85...1.1 Uc Unlatching: 0.85...1.1 Uc
Coil resistance (avg.)26 Ohm latching 68 °F (20 °C) 41 Ohm unlatching 68 °F (20 °C)
LX0FL224 — Performance & Durability
ParameterValue
Operating time50...100 ms unlatching 40...80 ms latching
Max. operating rate120 cyc/h 104 °F (40 °C)
Mechanical durability1 Mcycles

Product details

The LX0FL224 is a replacement contactor coil from the Schneider Electric TeSys F range, designed for use with TeSys F contactors. It provides the magnetic force to pull in and hold the contactor armature, with a dual-voltage control circuit: 220 V AC/DC for latching and 24 V AC/DC for unlatching. The control circuit accepts AC from 50 to 400 Hz or DC standard, giving flexibility across different control supply types. Operating time sits at 50 to 100 ms for unlatching and 40 to 80 ms for latching. Coil resistance measures 26 Ω for the latching winding and 41 Ω for the unlatching winding at 68 °F (20 °C).

Lifecycle reality — obsolete, source to order

These numbers give you a sense of the service life you can expect from a used or NOS unit.

What to check before ordering

Because this is an obsolete service part, verify that the coil's physical mounting and terminal arrangement match your existing TeSys F contactor. The dual-voltage winding (220 V latching / 24 V unlatching) is specific — confirm your control circuit can supply both voltages. The part ships as a single unit.

Frequently asked questions

What is the control voltage for this coil?

The latching coil is rated for 220 V AC/DC (50 to 400 Hz), and the unlatching coil is rated for 24 V AC/DC. Both windings accept voltage from 0.85 to 1.1 times the rated Uc.

What is the operating time of this contactor coil?

Unlatching time is 50 to 100 ms, and latching time is 40 to 80 ms.

How do I source an obsolete LX0FL224?

Submit an RFQ. Because the part is obsolete, we source it from the independent market — surplus stock, NOS, or broker inventory. No factory lead time applies.

MPN
LX0FL224