Schneider Electric LX1D6SF5 — Contactor & Starter Coils

TeSys LX1D6SF5 Contactor Coil, 500 V AC 50 Hz, Obsolete

MPNLX1D6SF5
Active

Telemecanique TeSys Deca, contactor coil LX1D6SF5, 500 V AC 50 Hz control voltage, 668 Ohm at 68 °F (20 °C), 200 VA inrush.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX1D6SF5 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX1D6
Coil technologyWithout built-in suppressor module
LX1D6SF5 — Electrical
ParameterValue
Control circuit voltage [Uc]500 V AC 50 Hz
Control circuit typeAC 50 Hz
Control circuit voltage limitsDrop-out: 0.3...0.6 Uc at 50/60 Hz (at Operational: 0.8...1.1 Uc at 50 Hz (at Operational: 0.85...1.1 Uc at 60 Hz (at <131 °F (55 °C))
Coil resistance (avg.)668 Ohm 68 °F (20 °C)
Coil inductance (closed circuit)38 H
LX1D6SF5 — Power & Thermal
ParameterValue
Inrush power (VA)200 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))
Hold-in power (VA)20 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation6...10 W 50/60 Hz
LX1D6SF5 — Performance & Durability
ParameterValue
Max. operating rate3600 cyc/h 140 °F (60 °C)
Mechanical durability10 Mcycles
LX1D6SF5 — Environmental
ParameterValue
Operating temperature23...140 °F (-5...60 °C)

Product details

The LX1D6SF5 is a contactor coil from the TeSys Deca series, designed to mount onto the corresponding contactor frame. It operates on a 500 V AC 50 Hz control circuit, drawing 200 VA inrush at 50 Hz cos phi 0.75 and 20 VA holding at 50 Hz cos phi 0.3, both measured at 68 °F (20 °C). The coil resistance sits at 668 Ohm at 20 °C, with an inductance of 38 H when the circuit is closed. It's built without a built-in suppressor module, so you'll need to add external suppression if the application demands it—common practice for inductive load switching in panel builds.

Voltage Tolerances and Thermal Behaviour

The coil's control circuit voltage limits are defined: drop-out occurs between 0.3 and 0.6 Uc at 50/60 Hz, and operational pick-up requires 0.8 to 1.1 Uc at 50 Hz (0.85 to 1.1 Uc at 60 Hz), all at temperatures below 131 °F (55 °C). This means at nominal 500 V AC, the coil drops out somewhere between 150 V and 300 V, and needs at least 400 V to pull in reliably at 50 Hz. Heat dissipation runs 6 to 10 W at 50/60 Hz—enough to warm the panel locally, so ensure ventilation around the contactor stack. Ambient temperature range for operation is 23 to 140 °F (-5 to 60 °C).

Frequently asked questions

What is the control voltage for this coil?

The control circuit voltage is 500 V AC at 50 Hz, with a drop-out range of 0.3 to 0.6 Uc and an operational pick-up range of 0.8 to 1.1 Uc at 50 Hz.

Does this coil include a built-in suppressor module?

No, the LX1D6SF5 is specified as without a built-in suppressor module. External suppression is required for inductive load switching.

What is the mechanical durability of this coil?

The mechanical durability is rated at 10 million cycles, with a maximum operating rate of 3600 cycles per hour at 140 °F (60 °C).