Skip to main content
Schneider Electric LX1FF032 — Contactor & Starter Coils

Schneider Electric LX1FF032 TeSys F Contactor Coil, 32 V AC

MPNLX1FF032
Active

Schneider Electric TeSys F series, LX1FF032 contactor coil, 32 V AC 50 Hz control circuit, 550 VA inrush.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LX1FF032 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX1FF
Coil technologyWithout built-in suppressor module
LX1FF032 — Electrical
ParameterValue
Control circuit voltage [Uc]32 V AC 50 Hz
Control circuit typeAC 50 Hz
Control circuit voltage limitsDrop-out 0.35...0.55 Uc 50/60 Hz 131 °F (55 °C)) Operational 0.85...1.1 Uc 50/60 Hz 131 °F (55 °C))
Coil resistance (avg.)0.51 Ohm 68 °F (20 °C)
Coil inductance (closed circuit)0.07 H
LX1FF032 — Power & Thermal
ParameterValue
Inrush power (VA)550 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Hold-in power (VA)45 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation12...16 W 50 Hz
LX1FF032 — Performance & Durability
ParameterValue
Operating time23...35 ms closing 5...15 ms opening
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX1FF032 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX1FF032 is a replacement coil for the TeSys F contactor range, designed for 32 V AC 50 Hz control circuits. It is the component that pulls in and holds the contactor armature — without it, the main power poles don't close. Rated for 32 V AC at 50 Hz, this coil draws 550 VA inrush at 68 °F (20 °C) with a cos phi of 0.3, then settles to 45 VA holding power. The 12 to 16 W heat dissipation at 50 Hz means the panel designer needs to account for that thermal load inside the enclosure, especially if multiple contactors are ganged.

Key Specs for Fit Verification

Operating time is 23 to 35 ms closing and 5 to 15 ms opening. The coil has no built-in suppressor module, so if your application requires EMI suppression or flyback protection, you will need to add an external RC snubber or varistor across the coil terminals. The control circuit voltage limits are drop-out at 0.35 to 0.55 Uc and operational at 0.85 to 1.1 Uc at 50/60 Hz. Average coil resistance is 0.51 Ohm at 68 °F (20 °C), and the inductance of the closed circuit is 0.07 H. Ambient air temperature range for operation is 23 to 131 °F (-5 to 55 °C).

Frequently asked questions

What is the TeSys range for this coil?

The LX1FF032 belongs to the TeSys F range of contactors and accessories from Schneider Electric.

What are the key electrical ratings for this coil?

The coil is rated for 32 V AC 50 Hz control voltage, with 550 VA inrush power and 45 VA holding power at 68 °F (20 °C). Heat dissipation is 12 to 16 W at 50 Hz.

MPN