Schneider Electric LX1FF052 — Contactor & Starter Coils

Schneider LX1FF052 TeSys F Contactor Coil, 52 V AC 50 Hz, Ob

MPNLX1FF052
Obsolete

Schneider Electric, TeSys F, contactor coil, LX1FF052, 52 V AC 50 Hz, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX1FF052 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX1FF
Coil technologyWithout built-in suppressor module
LX1FF052 — Electrical
ParameterValue
Control circuit voltage [Uc]52 V AC 50 Hz
Control circuit typeAC 50 Hz
Control circuit voltage limitsDrop-out 0.35...0.55 Uc 50/60 Hz 131 °F (55 °C)) Operational 0.85...1.1 Uc 50/60 Hz 131 °F (55 °C))
Coil resistance (avg.)1.41 Ohm 68 °F (20 °C)
Coil inductance (closed circuit)0.19 H
LX1FF052 — Power & Thermal
ParameterValue
Inrush power (VA)550 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Hold-in power (VA)45 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation12...16 W 50 Hz
LX1FF052 — Performance & Durability
ParameterValue
Operating time23...35 ms closing 5...15 ms opening
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX1FF052 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The Schneider Electric LX1FF052 is a replacement contactor coil from the TeSys F range, designed for 52 V AC 50 Hz control circuits. It is the energizing element that pulls in the main contactor armature, rated for 550 VA inrush at 50 Hz cos φ 0.3 and 45 VA hold-in consumption at the same power factor. Closing time runs 23 to 35 ms, opening 5 to 15 ms.

The 52 V AC 50 Hz coil voltage is non-standard compared to common 110 V or 230 V control transformers — verify your control circuit voltage matches exactly. The dropout threshold is 0.35 to 0.55 Uc (about 18 to 29 V) at 55 °C, and the operational range is 0.85 to 1.1 Uc (44 to 57 V). This means the coil will reliably pick up at 44 V and drop out below about 29 V, which is important for brownout ride-through or undervoltage release coordination. Heat dissipation runs 12 to 16 W at 50 Hz, so the coil contributes measurable heat inside the enclosure. In a densely packed panel with multiple TeSys F contactors, this adds up — account for it in your thermal budget. The coil has no built-in suppressor module, so you must add an external RC snubber or varistor across the coil terminals to limit switching transients and protect the PLC output driving it. That's about 40 operations per minute — fine for most conveyor or pump cycling, but not for high-speed indexing applications.

Frequently asked questions

What is the control circuit voltage for this coil?

The LX1FF052 is rated for 52 V AC at 50 Hz. The operational voltage range is 0.85 to 1.1 Uc (44 to 57 V), and dropout occurs at 0.35 to 0.55 Uc (about 18 to 29 V) at 55 °C.

Does this coil include a built-in suppressor module?

No. The LX1FF052 is specified as 'without built-in suppressor module'. An external RC snubber or varistor must be added across the coil terminals for transient suppression.

What is the mechanical durability of this coil?

The LX1FF052 is rated for 10 million mechanical cycles, with a maximum operating rate of 2400 cycles per hour at 55 °C.

MPN
LX1FF052