Skip to main content
Schneider Electric LX1FF1000 — Contactor & Starter Coils

Schneider Electric LX1FF1000 TeSys F Contactor Coil, 1000 V

MPNLX1FF1000
Active

Schneider Electric TeSys F, contactor coil LX1FF1000, 1000 V AC 50 Hz, 23...35 ms closing, 5...15 ms opening, without built-in suppressor module.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LX1FF1000 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX1FF
Coil technologyWithout built-in suppressor module
LX1FF1000 — Electrical
ParameterValue
Control circuit voltage [Uc]1000 V AC 50 Hz
Control circuit typeAC 50 Hz
Control circuit voltage limitsDrop-out 0.35...0.55 Uc 50/60 Hz 131 °F (55 °C)) Operational 0.85...1.1 Uc 50/60 Hz 131 °F (55 °C))
Coil resistance (avg.)610 Ohm 68 °F (20 °C)
Coil inductance (closed circuit)68.5 H
LX1FF1000 — Power & Thermal
ParameterValue
Inrush power (VA)550 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Hold-in power (VA)45 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation12...16 W 50 Hz
LX1FF1000 — Performance & Durability
ParameterValue
Operating time23...35 ms closing 5...15 ms opening
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX1FF1000 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX1FF1000 is a TeSys F contactor coil from Schneider Electric, designed to actuate the main contactor in a motor starter or power switching assembly. It operates on a 1000 V AC 50 Hz control circuit, drawing 550 VA inrush at 20 °C and 45 VA hold-in power at the same temperature.

Key electrical characteristics

The coil has an average resistance of 610 Ohm at 68 °F (20 °C) and an inductance of 68.5 H when closed. Its control circuit voltage limits are: drop-out at 0.35...0.55 Uc and operational range of 0.85...1.1 Uc at 50/60 Hz and 131 °F (55 °C). This means the coil reliably picks up at 850 V AC and drops out between 350 and 550 V AC, which is important for brownout ride-through planning. Operating time is 23...35 ms closing and 5...15 ms opening. That 5 ms minimum opening time is fast enough for most safety circuits but verify it coordinates with your upstream breaker's clearing time if used in a direct-on-line start.

Thermal and mechanical performance

Heat dissipation runs 12...16 W at 50 Hz, so factor that into your panel's thermal budget — a densely packed enclosure with several TeSys F contactors running continuously will need ventilation or derating. That rate suits moderate-speed conveyor or pump cycling but not high-speed stamping press applications. Ambient air temperature for operation is 23...131 °F (-5...55 °C). The coil technology is without built-in suppressor module, so you'll need to add an external RC snubber or varistor across the coil if driving it from a PLC output or solid-state relay to prevent voltage spikes.

Frequently asked questions

What is the closest alternative to LX1FF1000 in the TeSys F family?

Within the TeSys F range, the primary alternative would be a coil with a different control voltage. There is no pin-compatible substitute with the same 1000 V AC 50 Hz rating; the LX1FF1000 is the specific order code for that voltage. If your control voltage differs, the LX1FF family includes coils for 110 V, 220 V, 380 V, and 480 V AC.

How do I source the LX1FF1000?

This part is quoted to order against an RFQ. Submit your quantity and required delivery window, and we will return a firm price and lead time.

MPN
LX1FF1000