Skip to main content
Schneider Electric LX1FF170 — Contactor & Starter Coils

Schneider LX1FF170 TeSys F Contactor Coil, 170 VAC 50 Hz

MPNLX1FF170
Obsolete

Schneider Electric TeSys F series, LX1FF170 contactor coil, 170 V AC 50 Hz control circuit, 550 VA inrush, 45 VA hold-in.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX1FF170 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX1FF
Coil technologyWithout built-in suppressor module
LX1FF170 — Electrical
ParameterValue
Control circuit voltage [Uc]170 V AC 50 Hz
Control circuit typeAC 50 Hz
Control circuit voltage limitsDrop-out 0.35...0.55 Uc 50/60 Hz 131 °F (55 °C)) Operational 0.85...1.1 Uc 50/60 Hz 131 °F (55 °C))
Coil resistance (avg.)15.02 Ohm 68 °F (20 °C)
Coil inductance (closed circuit)2.03 H
LX1FF170 — Power & Thermal
ParameterValue
Inrush power (VA)550 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Hold-in power (VA)45 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation12...16 W 50 Hz
LX1FF170 — Performance & Durability
ParameterValue
Operating time23...35 ms closing 5...15 ms opening
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX1FF170 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX1FF170 is a replacement contactor coil from the TeSys F range, designed to fit TeSys F contactor frames. It operates on a 170 V AC 50 Hz control circuit, drawing 550 VA inrush and 45 VA hold-in power at 20 °C with a cos phi of 0.3. Closing time runs 23 to 35 ms, opening 5 to 15 ms — fast enough for standard motor switching but not for high-speed logic applications.

Sourcing reality for an obsolete part

Schneider has marked the LX1FF170 as obsolete.

Coil electrical characteristics

The coil has no built-in suppressor module. Average DC resistance is 15.02 Ω at 68 °F (20 °C); inductance of the closed circuit is 2.03 H. Drop-out occurs between 0.35 and 0.55 Uc, and the coil operates between 0.85 and 1.1 Uc at 55 °C.

Thermal and mechanical limits

Heat dissipation runs 12 to 16 W at 50 Hz — enough to consider ventilation if multiple coils are packed tightly in a panel.

Frequently asked questions

Does this coil include a built-in suppressor?

No. The coil is supplied without a built-in suppressor module. An external RC snubber or varistor must be added if the application requires EMI suppression or contact protection.

What are the inrush and hold-in power ratings?

Inrush power is 550 VA at 50 Hz with cos phi 0.3; hold-in power drops to 45 VA under the same conditions. These values are measured at 68 °F (20 °C).

MPN
LX1FF170