The LX1FG026 is a TeSys F contactor coil from Schneider Electric, rated for 26 V AC at 50 Hz control circuits. It pulls 805 VA inrush at cos φ 0.3 and settles to 55 VA hold-in — numbers you need to size the control transformer feeding it. No built-in suppressor module means you add an RC snubber or varistor across the coil if the PLC output or relay driving it expects one.
Drop-out threshold is 0.35 to 0.55 Uc; operational range is 0.85 to 1.1 Uc at 50/60 Hz and 131 °F (55 °C). Heat dissipation is 18 to 24 W at 50 Hz.
This part is marked obsolete by Schneider Electric.
This coil mounts into TeSys F contactor frames — the full-size F-line power stack. It is an AC 50 Hz coil only; do not apply it on 60 Hz control circuits without checking the drop-out and operational limits, which are specified at 50/60 Hz. The 20 to 35 ms closing time and 7 to 15 ms opening time are standard for this frame class and coordinate with typical PLC scan cycles or relay logic.