Schneider Electric LX1FG032 — Contactor & Starter Coils

Schneider LX1FG032 TeSys F Contactor Coil, 32 V AC 50 Hz

MPNLX1FG032
Active

Schneider Electric TeSys F contactor coil, LX1FG032, 32 V AC 50 Hz, 805 VA inrush, 55 VA hold, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX1FG032 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX1FG
Coil technologyWithout built-in suppressor module
LX1FG032 — Electrical
ParameterValue
Control circuit voltage [Uc]32 V AC 50 Hz
Control circuit typeAC 50 Hz
Control circuit voltage limitsDrop-out 0.35...0.55 Uc 50/60 Hz 131 °F (55 °C)) Operational 0.85...1.1 Uc 50/60 Hz 131 °F (55 °C))
Coil resistance (avg.)0.3 Ohm 68 °F (20 °C)
Coil inductance (closed circuit)0.05 H
LX1FG032 — Power & Thermal
ParameterValue
Inrush power (VA)805 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Hold-in power (VA)55 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation18...24 W 50 Hz
LX1FG032 — Performance & Durability
ParameterValue
Operating time20...35 ms closing 7...15 ms opening
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX1FG032 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX1FG032 is a replacement coil for the TeSys F contactor range, wound for 32 V AC at 50 Hz. It pulls 805 VA inrush at 50 Hz (cos φ 0.3) and settles to 55 VA hold-in — the heat dissipation runs 18 to 24 W at 50 Hz, so the enclosure needs some breathing if the contactor cycles hard. Closing time is 20 to 35 ms; opening is 7 to 15 ms. Drop-out voltage sits between 0.35 and 0.55 Uc at 55 °C; pick-up is 0.85 to 1.1 Uc. No built-in suppressor module, so you'll add a varistor or RC snubber across the coil if the PLC output or relay driving it needs protection.

Ambient temperature range for operation is -5 to 55 °C. The coil's DC resistance is 0.3 ohm at 20 °C, and closed-circuit inductance is 0.05 H. These numbers matter if you're calculating thermal rise in a densely packed panel or sizing the control transformer.

Frequently asked questions

What are the key electrical ratings for this coil?

Control voltage is 32 V AC 50 Hz. Inrush power is 805 VA at 50 Hz (cos φ 0.3); hold-in power is 55 VA at 50 Hz (cos φ 0.3). Heat dissipation is 18 to 24 W at 50 Hz.

Does the coil include a built-in suppressor?

No — it is specified without a built-in suppressor module. An external varistor or RC snubber should be added for inductive kickback protection.