Skip to main content
Schneider Electric LX1FG076 — Contactor & Starter Coils

Schneider LX1FG076 TeSys F Contactor Coil, 76 V AC 50 Hz, Ob

MPNLX1FG076
Obsolete

Schneider Electric TeSys F contactor coil, LX1FG076, 76 V AC 50 Hz, 18–24 W heat dissipation, 10 Mcycles mechanical durability.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX1FG076 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX1FG
Coil technologyWithout built-in suppressor module
LX1FG076 — Electrical
ParameterValue
Control circuit voltage [Uc]76 V AC 50 Hz
Control circuit typeAC 50 Hz
Control circuit voltage limitsDrop-out 0.35...0.55 Uc 50/60 Hz 131 °F (55 °C)) Operational 0.85...1.1 Uc 50/60 Hz 131 °F (55 °C))
Coil resistance (avg.)1.77 Ohm 68 °F (20 °C)
Coil inductance (closed circuit)0.3 H
LX1FG076 — Power & Thermal
ParameterValue
Inrush power (VA)805 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Hold-in power (VA)55 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation18...24 W 50 Hz
LX1FG076 — Performance & Durability
ParameterValue
Operating time20...35 ms closing 7...15 ms opening
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX1FG076 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX1FG076 is a replacement coil for Schneider Electric TeSys F contactors, wound for 76 V AC 50 Hz control circuits. It draws 805 VA inrush at 50 Hz (cos φ 0.3) and settles to 55 VA holding, with heat dissipation of 18 to 24 W at 50 Hz.

Coil specs that matter for fit

Coil resistance is 1.77 Ω at 20 °C, and closed-circuit inductance is 0.3 H. The control voltage limits are 0.85 to 1.1 Uc for pickup and 0.35 to 0.55 Uc for dropout at 55 °C — so on a 76 V nominal circuit, pickup is guaranteed between roughly 65 and 84 V, and dropout between 27 and 42 V. No built-in suppressor module, so you'll need an external RC snubber or varistor across the coil if driving from a PLC or solid-state output.

Frequently asked questions

What is the closest alternative to the LX1FG076?

No official successor is listed. A functionally equivalent coil would need to match the 76 V AC 50 Hz control voltage, the TeSys F mounting footprint, and the 18–24 W heat dissipation class. Check the TeSys F coil family for a different voltage if your control circuit can be adapted.

How do I source the LX1FG076 now that it is obsolete?

Through the surplus and independent distributor channel. Submit an RFQ; we source against verified broker inventory. No factory lead time applies.

MPN