Skip to main content
Schneider Electric LX1FG2206 — Contactor & Starter Coils

TeSys LX1FG2206 contactor coil, 265-277 V AC 60 Hz, obsolete

MPNLX1FG2206
Obsolete

Schneider Electric TeSys F contactor coil, LX1FG2206, 265-277 V AC 60 Hz, 805 VA inrush, 55 VA hold-in, obsolete.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LX1FG2206 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX1FG
Coil technologyWithout built-in suppressor module

Electrical

LX1FG2206 — Electrical
ParameterValue
Control circuit voltage [Uc]265...277 V AC 60 Hz
Control circuit typeAC 50 Hz
Control circuit voltage limitsDrop-out 0.35...0.55 Uc 50/60 Hz 131 °F (55 °C)) Operational 0.85...1.1 Uc 50/60 Hz 131 °F (55 °C))
Coil resistance (avg.)370 Ohm 68 °F (20 °C)
Coil inductance (closed circuit)51.6 H

Power & Thermal

LX1FG2206 — Power & Thermal
ParameterValue
Inrush power (VA)805 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Hold-in power (VA)55 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation18...24 W 50 Hz

Performance & Durability

LX1FG2206 — Performance & Durability
ParameterValue
Operating time20...35 ms closing 7...15 ms opening
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles

Environmental

LX1FG2206 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX1FG2206 is a TeSys F contactor coil from Schneider Electric, designed as a replacement or spare coil for TeSys F contactors. It operates on a 265-277 V AC 60 Hz control circuit, drawing 805 VA inrush power and 55 VA hold-in power at 50 Hz. The coil has an average resistance of 370 Ohm at 68 °F (20 °C) and dissipates 18-24 W of heat at 50 Hz. It has a mechanical durability of 10 million cycles and a maximum operating rate of 2400 cycles per hour at 131 °F (55 °C).

The control circuit voltage is 265-277 V AC 60 Hz. Dropout voltage is 0.35-0.55 Uc and operational range is 0.85-1.1 Uc at 50/60 Hz and 131 °F (55 °C). The 805 VA inrush power is the peak draw when the coil first energizes — this determines the sizing of the control transformer or power supply feeding it. The 55 VA hold-in power is the steady-state draw once the contactor is sealed, which governs continuous heat dissipation in the panel. Operating time is 20-35 ms closing and 7-15 ms opening. This is typical for a contactor coil of this size and matters for coordination in fast-switching applications like motor reversing or inching circuits.

This coil is a direct replacement for TeSys F contactors that use the LX1FG coil platform. It mounts onto the contactor's magnet assembly and is wired to the control circuit. The coil has no built-in suppressor module, so an external RC snubber or varistor must be added if the control circuit requires surge suppression — common practice in PLC-driven panels where the coil is switched by a solid-state output. In a panel with multiple contactors running near the 55 °C limit, the 18-24 W heat dissipation per coil adds up — factor this into the panel's thermal budget.

Frequently asked questions

What is the control voltage and coil draw for this part?

The control circuit voltage is 265-277 V AC 60 Hz. Inrush power is 805 VA at 50 Hz, and hold-in power is 55 VA at 50 Hz. Average coil resistance is 370 Ohm at 68 °F (20 °C).

Does this coil have a built-in suppressor?

No, the coil technology is listed as 'without built-in suppressor module'. An external suppression device (RC snubber or varistor) must be added if the control circuit requires it.

What is the operating temperature range?

The ambient air temperature for operation is 23 to 131 °F (-5 to 55 °C). The maximum operating rate at 131 °F (55 °C) is 2400 cycles per hour.

MPN
LX1FG2206