Schneider Electric LX1FG264 — Contactor & Starter Coils

TeSys LX1FG264 Contactor Coil, 264 V AC 50 Hz

MPNLX1FG264
Active

Schneider Electric TeSys F contactor coil, LX1FG264, 264 V AC 50 Hz, 805 VA inrush, 55 VA hold-in, 18-24 W heat dissipation.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LX1FG264 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX1FG
Coil technologyWithout built-in suppressor module

Electrical

LX1FG264 — Electrical
ParameterValue
Control circuit voltage [Uc]264 V AC 50 Hz
Control circuit typeAC 50 Hz
Control circuit voltage limitsDrop-out 0.35...0.55 Uc 50/60 Hz 131 °F (55 °C)) Operational 0.85...1.1 Uc 50/60 Hz 131 °F (55 °C))
Coil resistance (avg.)24.52 Ohm 68 °F (20 °C)
Coil inductance (closed circuit)3.7 H

Power & Thermal

LX1FG264 — Power & Thermal
ParameterValue
Inrush power (VA)805 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Hold-in power (VA)55 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation18...24 W 50 Hz

Performance & Durability

LX1FG264 — Performance & Durability
ParameterValue
Operating time20...35 ms closing 7...15 ms opening
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles

Environmental

LX1FG264 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX1FG264 is a replacement coil for the TeSys F contactor range, wound for 264 V AC 50 Hz control circuits. It pulls 805 VA inrush at 50 Hz (cos φ 0.3) and settles to 55 VA hold-in — the inrush figure is what the control transformer and wiring need to handle, not just the sealed draw. Heat dissipation runs 18 to 24 W at 50 Hz, so panel thermal rise is a real consideration if multiple coils are ganged on the same enclosure.

Switching performance and duty cycle

Closing time is 20 to 35 ms, opening 7 to 15 ms. That's fast enough for most motor-start and lighting contactor applications, but if you're sequencing contactors in a reversing starter, account for the 20 ms minimum close time in your interlock timing. The coil is rated for 2400 cycles per hour at 131 °F (55 °C) ambient, and mechanical durability is 10 million cycles — the coil itself won't be the wear-out item in normal use.

Coil voltage tolerance and suppressor note

Pickup voltage range is 0.85 to 1.1 Uc at 50/60 Hz and 131 °F (55 °C); dropout is 0.35 to 0.55 Uc. That means the coil will pull in reliably down to about 224 V AC and drop out below roughly 145 V AC — useful to know if your control supply sags under heavy load. The coil ships without a built-in suppressor module, so you'll need to add an external RC snubber or varistor across the coil if you're switching it with a PLC output or solid-state relay. Coil resistance is 24.52 Ω at 68 °F (20 °C); inductance of the closed circuit is 3.7 H.

Frequently asked questions

What is the closest alternative to the LX1FG264?

There is no pin-compatible drop-in alternative outside the TeSys F platform. The LX1FG family includes other coil voltages for the same contactor frame, but the 264 V AC 50 Hz winding is specific to this order code.

What control circuit voltage does the LX1FG264 require?

The coil is rated for 264 V AC at 50 Hz. Pickup range is 0.85 to 1.1 Uc (approx. 224 to 290 V AC), dropout is 0.35 to 0.55 Uc (approx. 92 to 145 V AC).

Does the LX1FG264 include a built-in coil suppression module?

No, the coil ships without a built-in suppressor module. An external RC snubber or varistor must be added when switching with a PLC output or solid-state relay.

What is the heat dissipation of the LX1FG264?

Heat dissipation is 18 to 24 W at 50 Hz. This should be factored into panel thermal calculations, especially when multiple coils are installed in the same enclosure.