TeSys F, contactor coil, LX1FG600, 600 V AC 50 Hz, 805 VA inrush, 18-24 W heat dissipation, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX1FG600 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX1FG
Coil technologyWithout built-in suppressor module
LX1FG600 — Electrical
ParameterValue
Control circuit voltage [Uc]600 V AC 50 Hz
Control circuit typeAC 50 Hz
Control circuit voltage limitsDrop-out 0.35...0.55 Uc 50/60 Hz 131 °F (55 °C)) Operational 0.85...1.1 Uc 50/60 Hz 131 °F (55 °C))
Coil resistance (avg.)124.2 Ohm 68 °F (20 °C)
Coil inductance (closed circuit)18.25 H
LX1FG600 — Power & Thermal
ParameterValue
Inrush power (VA)805 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Hold-in power (VA)55 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation18...24 W 50 Hz
LX1FG600 — Performance & Durability
ParameterValue
Operating time20...35 ms closing 7...15 ms opening
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX1FG600 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX1FG600 is a TeSys F contactor coil rated for 600 V AC 50 Hz control circuits, designed as a replacement coil for the TeSys F contactor range. The part is now classified as obsolete per the manufacturer's lifecycle record.

Key electrical characteristics

The coil draws 805 VA inrush at 50 Hz (cos phi 0.3) and holds at 55 VA, dissipating 18 to 24 W during continuous operation. These figures set the transformer sizing and thermal budget inside the panel. Control voltage limits are specified for 50/60 Hz at 131 °F (55 °C): drop-out occurs between 0.35 and 0.55 Uc, and the operational range is 0.85 to 1.1 Uc. This defines the hold-in margin for brownout conditions. Closing time is 20 to 35 ms, opening time 7 to 15 ms. The coil has no built-in suppressor module; an external RC snubber or varistor must be added across the coil terminals for inductive load switching.

Mechanical and thermal ratings

Ambient air temperature for operation spans 23 to 131 °F (-5 to 55 °C). Average coil resistance is 124.2 ohms at 68 °F (20 °C), with an inductance of 18.25 H in the closed circuit. These values are useful for verifying coil integrity with a multimeter during troubleshooting.

Frequently asked questions

What is the LX1FG600's listed range and category?

It belongs to the TeSys range, specifically the TeSys F contactor family. Its internal category is 22341-CONTACTOR,D,K,&F ACCESS, indicating it is a contactor accessory for those frame sizes.

What are the key electrical ratings for the LX1FG600 coil?

The coil is rated for 600 V AC 50 Hz control circuits. Inrush power is 805 VA at 50 Hz (cos phi 0.3), hold-in power is 55 VA, and continuous heat dissipation is 18 to 24 W.

Does the LX1FG600 include a built-in coil suppression module?

No. The coil technology is listed as 'without built-in suppressor module'. An external suppression device (RC snubber or varistor) must be added across the coil terminals to protect against voltage spikes.

How do I source the LX1FG600 given its obsolete status?

Since the part is obsolete, it must be sourced through surplus or broker channels. Submit an RFQ with your target quantity; availability and pricing are confirmed on a per-order basis.