It operates on a 200 V AC 50 Hz / 200-220 V AC 60 Hz control circuit. Rated for a maximum operating rate of 2400 cycles per hour at 131 °F (55 °C), with an opening time of 100-170 ms and closing time of 40-65 ms. Heat dissipation is 8 W across 40-400 Hz. Control voltage limits: dropout at 0.35-0.55 Uc, operational at 0.85-1.1 Uc, both at 50/60 Hz and 131 °F (55 °C). The coil has no built-in suppressor module — an external RC snubber or varistor is needed across the coil terminals if driving from a PLC output or solid-state relay.

Schneider LX1FH22062 TeSys contactor coil, 200-220 V AC, obs
MPNLX1FH22062
Active
Schneider Electric TeSys LX1F contactor coil, LX1FH22062, 200-220 V AC 50/60 Hz control circuit, obsolete status.
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Product type | Contactor coil |
| Product range | TeSys |
| Device short name | LX1FH |
| Coil technology | Without built-in suppressor module |
| Parameter | Value |
|---|---|
| Control circuit voltage [Uc] | 200 V AC 50 Hz 200...220 V AC 60 Hz |
| Control circuit type | AC 50/60 Hz |
| Control circuit voltage limits | Drop-out 0.35...0.55 Uc 50/60 Hz 131 °F (55 °C)) Operational 0.85...1.1 Uc 50/60 Hz 131 °F (55 °C)) |
| Parameter | Value |
|---|---|
| Heat dissipation | 8 W 40...400 Hz |
| Parameter | Value |
|---|---|
| Operating time | 100...170 ms opening 40...65 ms closing |
| Max. operating rate | 2400 cyc/h 131 °F (55 °C) |
| Parameter | Value |
|---|---|
| Operating temperature | 23...131 °F (-5...55 °C) |
Product details
Frequently asked questions
What is the control voltage for this coil?
200 V AC at 50 Hz, and 200-220 V AC at 60 Hz. The control circuit is AC 50/60 Hz only.
Does this coil have a built-in suppressor?
No. The coil technology is listed as 'Without built-in suppressor module'. You must add an external suppression device (RC snubber or varistor) across the coil terminals for inductive load switching.
What is the operating temperature range?
-5 to 55 °C (23-131 °F) for operation.
MPN
LX1FH22062