Skip to main content
Schneider Electric LX1FH7002 — Contactor & Starter Coils

TeSys LX1FH7002 Contactor Coil, 700 VAC 40-400 Hz, Obsolete

MPNLX1FH7002
Active

Schneider Electric TeSys F contactor coil, LX1FH7002, 700 V AC 40...400 Hz, 650 VA inrush, 10 VA hold, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX1FH7002 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX1FH
Coil technologyWithout built-in suppressor module
LX1FH7002 — Electrical
ParameterValue
Control circuit voltage [Uc]700 V AC 40...400 Hz
Control circuit typeAC at 40...400 Hz
Control circuit voltage limitsDrop-out: 0.35...0.55 Uc 40...400 Hz (at 55 °C) Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C)
Coil resistance (avg.)0.8 Ohm inrush at 20 °C 20 Ohm holding at 20 °C
LX1FH7002 — Power & Thermal
ParameterValue
Inrush power (VA)650 VA 40...400 Hz cos phi 0.9 (at 20 °C)
Hold-in power (VA)10 VA 40...400 Hz cos phi 0.3 (at 20 °C)
Heat dissipation8 W at 40...400 Hz
LX1FH7002 — Performance & Durability
ParameterValue
Operating time100...170 ms opening 40...65 ms closing
Max. operating rate2400 cyc/h 55 °C
Mechanical durability10 Mcycles
LX1FH7002 — Environmental
ParameterValue
Operating temperature-5...55 °C

Product details

The LX1FH7002 is a TeSys F contactor coil from Schneider Electric, designed to operate the main poles of a TeSys F contactor at 700 V AC, 40...400 Hz. It is a replacement coil, not a complete contactor — you pair it with the matching contactor frame. This coil draws 650 VA inrush at 20 °C (cos φ 0.9) and settles to 10 VA holding power (cos φ 0.3). The 8 W heat dissipation at rated frequency means the panel builder should allow airflow around the contactor — especially if multiple units are ganged. Operating time is 100...170 ms to open, 40...65 ms to close — typical for a large-frame AC coil. The mechanical durability of 10 Mcycles is generous for a coil this size, but the maximum operating rate of 2400 cycles/hour at 55 °C sets a practical limit for high-speed applications like motor reversing or capacitor switching.

Schneider has marked the LX1FH7002 as obsolete.

Electrical Fit — What the Ratings Mean

The control circuit voltage is 700 V AC, 40...400 Hz — this is a high-voltage coil, not a standard 24 V or 230 V unit. The operational voltage limits are 0.85...1.1 Uc (595...770 V AC) at 55 °C, and drop-out occurs at 0.35...0.55 Uc (245...385 V AC). If your control supply sags below 595 V, the contactor may not pull in reliably. Coil resistance is 0.8 Ω inrush and 20 Ω holding at 20 °C. The inrush current can be calculated from the 650 VA figure — roughly 0.93 A at 700 V — but the holding current drops to about 14 mA. The coil has no built-in suppressor module, so you must add an external RC snubber or varistor if driving it from a PLC output or solid-state relay. The coil is rated for AC control circuits only (40...400 Hz) — do not apply DC voltage.

Frequently asked questions

What replaces the LX1FH7002?

Schneider does not list a direct official successor for the LX1FH7002. The best path is to source the original coil through surplus channels or to evaluate a complete contactor assembly replacement that matches your control voltage and frame size.

What compliance documentation is available for this coil?

The evidence does not list RoHS, REACH, UL, or IEC certifications for this part. For compliance verification, request the manufacturer's original documentation from your sourcing partner.

What is the operating time of the LX1FH7002?

Opening time is 100...170 ms; closing time is 40...65 ms. These are typical for a large-frame AC contactor coil.

MPN