Schneider Electric LX1FH7502 — Contactor & Starter Coils

Schneider Electric LX1FH7502 TeSys Contactor Coil, 780-800 V

MPNLX1FH7502
Active

Schneider Electric TeSys LX1F series, LX1FH7502 contactor coil, 780..800 V AC 40/400 Hz, 8 W dissipation, 100-170 ms opening time.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LX1FH7502 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX1FH
Coil technologyWithout built-in suppressor module

Electrical

LX1FH7502 — Electrical
ParameterValue
Control circuit voltage [Uc]780...800 V AC 40...400 Hz
Control circuit typeAC 40...400 Hz
Control circuit voltage limitsDrop-out 0.35...0.55 Uc 40...400 Hz 131 °F (55 °C)) Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C))

Power & Thermal

LX1FH7502 — Power & Thermal
ParameterValue
Heat dissipation8 W 40...400 Hz

Performance & Durability

LX1FH7502 — Performance & Durability
ParameterValue
Operating time100...170 ms opening 40...65 ms closing
Max. operating rate2400 cyc/h 131 °F (55 °C)

Environmental

LX1FH7502 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX1FH7502 is a TeSys LX1F-series contactor coil rated for 780...800 V AC control circuits at 40 to 400 Hz. It pulls 8 W of heat dissipation during continuous operation, so panel ventilation or spacing from heat-sensitive components matters in a crowded enclosure. Opening time runs 100 to 170 ms; closing is faster at 40 to 65 ms. That spread matters for sequencing — if you're coordinating interlocking or safety circuits, the slower opening side sets the window you need to guarantee separation.

Control voltage limits and operating conditions

The coil holds in from 85% to 110% of rated Uc (operational range) and drops out between 35% and 55% Uc at 55 °C. That dropout threshold is low enough that a sagging line won't cause nuisance dropouts, but verify your supply's brownout behavior against the 0.35 Uc floor — roughly 273 V AC on a 780 V nominal tap. Rated for ambient temperatures from -5 to 55 °C. Maximum cycling rate is 2400 operations per hour at 55 °C — enough for most motor-starting duty, but if you're running a high-speed pick-and-place or cam-driven load, check the thermal accumulation against the 8 W dissipation figure.

Frequently asked questions

What is the control voltage for this coil?

Rated 780...800 V AC at 40 to 400 Hz. Dropout occurs at 0.35 to 0.55 Uc; operational hold range is 0.85 to 1.1 Uc.

What is the heat dissipation of LX1FH7502?

8 W across the 40 to 400 Hz range. Account for this in panel thermal calculations, especially in densely packed enclosures.

What is the operating time for this contactor coil?

Opening time is 100 to 170 ms; closing time is 40 to 65 ms. The opening window is the limiting factor for interlock timing.