Schneider Electric LX1FJ1000 — Contactor & Starter Coils

Schneider LX1FJ1000 TeSys F Contactor Coil, 1000 V AC, Obsol

MPNLX1FJ1000
Active

Schneider Electric TeSys F, contactor coil LX1FJ1000, 1000 V AC 40...400 Hz, 14 W heat dissipation, obsolete lifecycle.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX1FJ1000 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX1FJ
Coil technologyWithout built-in suppressor module
LX1FJ1000 — Electrical
ParameterValue
Control circuit voltage [Uc]1000 V AC 40...400 Hz
Control circuit typeAC 40...400 Hz
Control circuit voltage limitsOperational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C)) Drop-out 0.3...0.5 Uc 40...400 Hz 131 °F (55 °C))
Coil resistance (avg.)720 Ohm inrush 68 °F (20 °C) 19420 Ohm holding 68 °F (20 °C)
Coil inductance (closed circuit)84.6 H
LX1FJ1000 — Power & Thermal
ParameterValue
Inrush power (VA)1075 VA 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))
Hold-in power (VA)15 VA 40...400 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation14 W 40...400 Hz
LX1FJ1000 — Performance & Durability
ParameterValue
Operating time100...170 ms opening 40...75 ms closing
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX1FJ1000 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The Schneider LX1FJ1000 is a TeSys F contactor coil rated for 1000 V AC control circuits at 40...400 Hz. It's the replaceable coil assembly for a TeSys F frame contactor — the electromagnet that pulls the main contacts in when energized. Opening time runs 100...170 ms, closing 40...75 ms, so the mechanical response is on the slower side for a contactor this size; that matters if you're sequencing multiple contactors in a transfer scheme and need to guarantee break-before-make timing.

Coil electrical characteristics

The coil draws 1075 VA inrush at 68 °F (20 °C) and holds at 15 VA with a cos φ of 0.3. Average DC resistance is 720 Ω inrush and 19420 Ω holding at the same temperature. Heat dissipation is 14 W across the 40...400 Hz range — that's the heat the coil dumps into the contactor enclosure, so factor it into your panel thermal budget if you're running this in a sealed cabinet. The coil has no built-in suppressor module, so you'll need an external RC snubber or varistor across the terminals if the control circuit drives inductive loads nearby.

The LX1FJ coil snaps into the TeSys F contactor frame — no tools needed for the coil change, just a screwdriver to release the retaining clip. The control circuit voltage limits are 0.85...1.1 Uc for pickup and 0.3...0.5 Uc for drop-out at 131 °F (55 °C), so it holds in down to 850 V AC and drops out reliably below 500 V AC. Ambient operating range is -5...55 °C. The inductance of the closed circuit is 84.6 H, which is high enough that the back-EMF on de-energization can arc across un-suppressed contacts — again, fit that external suppressor.

Frequently asked questions

What replaces LX1FJ1000?

No official successor order code is listed in the lifecycle documentation. For a drop-in replacement, you would need to source the same LX1FJ1000 from surplus or broker channels, or re-engineer the control circuit for a different coil voltage.

What is the control voltage rating?

The coil is rated for 1000 V AC at 40...400 Hz. Operational pickup range is 0.85...1.1 Uc, and drop-out range is 0.3...0.5 Uc at 131 °F (55 °C).

Does this coil include a built-in surge suppressor?

No. The coil technology is listed as 'without built-in suppressor module'. An external RC snubber or varistor must be added to the control wiring for EMI suppression and contact protection.

MPN
LX1FJ1000