Schneider Electric TeSys LX1FK, contactor coil, 200..220 V AC 40...400 Hz, 100...170 ms opening 40...75 ms closing.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LX1FK2206 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX1FK
Coil technologyWithout built-in suppressor module

Electrical

LX1FK2206 — Electrical
ParameterValue
Control circuit voltage [Uc]200...220 V AC 40...400 Hz
Control circuit typeAC at 40...400 Hz

Performance & Durability

LX1FK2206 — Performance & Durability
ParameterValue
Operating time100...170 ms opening 40...75 ms closing
Max. operating rate2400 cyc/h 55 °C
Mechanical durability10 Mcycles

Product details

The LX1FK2206 is a replacement contactor coil from the Schneider TeSys range, designed to fit LX1F contactor frames. It operates on a 200...220 V AC control circuit at 40...400 Hz, with opening time of 100...170 ms and closing time of 40...75 ms. The coil carries a mechanical durability rating of 10 Mcycles and a maximum operating rate of 2400 cycles per hour at 55 °C.

The 200...220 V AC control voltage at 40...400 Hz means this coil is for standard line-voltage control circuits — common in European and Asian panels where 208-240 V control transformers are typical. The 100...170 ms opening time and 40...75 ms closing time are the mechanical stroke durations; for a contactor coil, these matter when coordinating with fast-acting safety circuits or PLC-driven outputs that expect a predictable dropout delay. The 10 Mcycles mechanical durability is the theoretical life of the coil mechanism under no-load switching — in practice, electrical life under full motor load will be shorter and depends on the contactor's utilization category.

Coil technology note

This coil is supplied without a built-in suppressor module. That means the end user must add an external RC snubber or varistor across the coil terminals if the control circuit drives inductive loads or if the PLC output card requires suppression to limit back-EMF. Standard practice in a panel is to fit a suppressor across the coil — the LX1FK2206 leaves that choice to the integrator.

Frequently asked questions

What is the closest alternative to LX1FK2206?

There is no official pin-compatible successor from Schneider. For a new design, select a current TeSys coil with the same 200-220 VAC control voltage and LX1F frame compatibility. For an existing BOM, the LX1FK2206 must be sourced through surplus channels.