Schneider Electric LX1FX280 — Contactor & Starter Coils

LX1FX280 TeSys F Contactor Coil, 265-277 V AC

MPNLX1FX280
Active

Schneider Electric TeSys F contactor coil, LX1FX280, 265-277 V AC 40-400 Hz, set of 2, 44 W heat dissipation.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LX1FX280 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX1FX
Coil technologyWithout built-in suppressor module

Electrical

LX1FX280 — Electrical
ParameterValue
Control circuit voltage [Uc]265...277 V AC 40...400 Hz
Control circuit typeAC 40...400 Hz
Control circuit voltage limitsOperational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C)) Drop-out 0.2...0.4 Uc 40...400 Hz 131 °F (55 °C))
Coil resistance (avg.)29.8 Ohm inrush 68 °F (20 °C) 1330 Ohm holding 68 °F (20 °C)
Coil inductance (closed circuit)1.25 H

Power & Thermal

LX1FX280 — Power & Thermal
ParameterValue
Inrush power (VA)2100 VA 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))
Hold-in power (VA)50 VA 40...400 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation44 W 40...400 Hz

Performance & Durability

LX1FX280 — Performance & Durability
ParameterValue
Operating time130...230 ms opening 40...80 ms closing
Max. operating rate600 cyc/h 131 °F (55 °C)
Mechanical durability5 Mcycles

Environmental

LX1FX280 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

Part identity and fit

The LX1FX280 is a TeSys F contactor coil — a replacement or spare coil for TeSys F contactors in the LX1FX family, supplied as a set of 2. Control circuit is AC 40-400 Hz, rated 265-277 V AC. Coil holds in at 0.85-1.1 Uc and drops out between 0.2-0.4 Uc at 131 °F (55 °C). Opening time is 130-230 ms, closing time 40-80 ms — the 40 ms close means it engages quickly for a coil of this class, but the 230 ms open window is wider than a DC coil; factor that into safety-circuit timing if the contactor drives an emergency-stop path.

Because it is a current-production part, the buyer can quote against an RFQ for scheduled delivery rather than hunting surplus. No official replacement exists; this is the direct order code for the 265-277 V AC coil.

Thermal and electrical load

Heat dissipation is 44 W at 40-400 Hz — enough that a densely packed panel should account for the thermal load when sizing cabinet ventilation or spacing adjacent components. Inrush power is 2100 VA at cos φ 0.9; hold-in power drops to 50 VA at cos φ 0.3. The inrush surge matters for transformer sizing or shared control-circuit supplies — a 50 VA hold-in is modest, but the 2100 VA peak at pull-in can drop a lightly loaded control transformer. Coil resistance: 29.8 Ω inrush, 1330 Ω holding at 68 °F (20 °C). No built-in suppressor module — if the contactor drives an inductive load, plan external RC snubber or varistor across the coil terminals to limit switching transients.

Mechanical endurance

Rated for 5 million mechanical cycles at a maximum operating rate of 600 cycles per hour at 131 °F (55 °C). That rate is typical for a contactor coil in a cycling application — conveyor indexing or pump sequencing — but sustained operation above 600 cyc/h will shorten life.

Frequently asked questions

What is the control voltage for this coil?

265-277 V AC, 40-400 Hz. Operational range is 0.85-1.1 Uc; drop-out is 0.2-0.4 Uc.

Does this coil include a built-in suppressor?

No — it is specified as without built-in suppressor module. An external RC snubber or varistor is recommended when switching inductive loads.

What is the heat dissipation of this coil?

44 W at 40-400 Hz. Account for this when sizing cabinet ventilation.

MPN
LX1FX280