Schneider Electric LX1G3TEHEA

TeSys Giga LX1G3TEHEA Contactor Coil, 48-130V AC/DC, 3P

MPN LX1G3TEHEA
Active

Schneider Electric TeSys Giga, contactor coil LX1G3TEHEA, 48-130V AC/DC 50/60 Hz, 3P, for LC1G630-800/3P advanced version, with built-in bidirectional peak limiting.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LX1G3TEHEA specifications
ParameterValue
Main product or component typeContactor coil
Coil voltage48...130 V AC/DC 50/60 Hz
IP ratingIP20
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-60...80 °C
Pollution degree3 conforming to IEC 60947-1
Depth211 mm
Width192 mm
Height130 mm
Mechanical life cycles5 Mcycles
Operating time20...35 ms opening 40...55 ms closing
Operating temperature-25...60 °C
Permissible ambient air temperature around the device-40...70 °C at Uc

Product details

This coil carries EN/IEC 60947-4-1, UL 60947-4-1A, and CSA C22.2 No. 60947-4-1 certifications. That means it is tested and listed for contactor duty in industrial control panels — not just a generic relay coil. The pollution degree 3 rating per IEC 60947-1 confirms it tolerates conductive pollution typical in factory environments without conformal coating.

Physical integration and wiring

Control circuit wiring uses push-in terminals accepting 0.2 to 2.5 mm² solid or stranded (with ferrule) or two 0.5 to 1.0 mm² conductors. Strip length and ferrule spec are standard; no special tooling needed.

Environmental limits and operating envelope

Permissible ambient around the device extends to -40 to 70 °C at Uc, but the 60 °C operating ceiling is the hard limit for cycle-rated duty. Altitude derating starts at 3000 m; above that, apply the derating factor per IEC 60947-1. Opening time is 20 to 35 ms; closing time is 40 to 55 ms. Those figures matter for coordination in safety circuits or sequential starting — you cannot treat it as instantaneous. EMC immunity meets IEC 60947-4-1 with criteria A, including 20 V/m radiated field immunity per EN/IEC 61000-4-3 and SEMI F47 voltage dip immunity for semiconductor fab equipment.

MPN
LX1G3TEHEA